z16f2811 ZiLOG Semiconductor, z16f2811 Datasheet - Page 99

no-image

z16f2811

Manufacturer Part Number
z16f2811
Description
High Performance Microcontrollers
Manufacturer
ZiLOG Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
z16f2811AL20AG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z16f2811AL20EG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z16f2811AL20SG
Manufacturer:
VISHAY
Quantity:
9 487
Part Number:
z16f2811AL20SG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z16f2811AL20SG
Manufacturer:
ZILOG
Quantity:
20 000
Part Number:
z16f2811FI20AG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z16f2811FI20EG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z16f2811FI20SG
Manufacturer:
Zilog
Quantity:
155
Table 43. Last IRQ Register (LASTIRQ)
PS022006-0207
RESET
FIELD
ADDR
BITS
R/W
Last IRQ Register
Interrupt Request 0 Register
Always 0
R
7
0
Reserved—These bits are reserved
WDTOSC—WDT Oscillator Fail
If this bit is 1, a WDT oscillator fail exception occurred. Writing 1 to this bit clears it to 0.
PRIOSC—Primary Oscillator Fail
If this bit is 1, a primary oscillator fail exception occurred. Writing 1 to this bit clears it
to 0.
WDT—Watchdog Timer Interrupt
If this bit is 1, a WDT exception occurred. Writing 1 to this bit clears it to 0.
When an interrupt occurs, the 5th bit value of the interrupt vector is stored in the register.
This register allows the software to determine which interrupt source was last serviced.
It is used by RTOS which have a single interrupt entry point. To implement this the
software must set all interrupt vectors to the entry point address. The entry point service
routine then reads this register to determine which source caused the interrupt or exception
and respond accordingly.
The interrupt request 0 (IRQ0) register (see
requests for both vectored and polled interrupts. When a request is presented to the
interrupt controller, the corresponding bit in the IRQ0 register becomes 1. If interrupts are
globally enabled (vectored interrupts), the interrupt controller passes an interrupt request
to the ZNEO CPU. If interrupts are globally disabled (polled interrupts), the ZNEO CPU
reads the interrupt request 0 register to determine if any interrupt requests are pending.
Writing 1 to the bits in this register clears the interrupt. The bits of this register are set by
writing 1 to the interrupt request 0 set regsiter (IRQ0SET) at address FF_E031H.
R/W
6
0
R/W
5
0
P R E L I M I N A R Y
IRQADR
R/W
4
0
FF_E023H
Table 44
R/W
3
0
on page 86) stores the interrupt
R/W
2
1
Product Specification
ZNEO
Interrupt Controller
R
1
0
Always 00
Z16F Series
R
0
0
85

Related parts for z16f2811