R88A-CNG02R Omron, R88A-CNG02R Datasheet - Page 260

no-image

R88A-CNG02R

Manufacturer Part Number
R88A-CNG02R
Description
Encoder Connector INC Motor
Manufacturer
Omron
Datasheet

Specifications of R88A-CNG02R

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
4
4-3 Wiring Conforming to EMC Directives
4-3
Wiring Method
4-27
Single-phase: 100 VAC
Three-phase: 200 VAC
Single-phase:
100 VAC
R88D-GTA5L/-GT01L/-GT02L/-GT04L/-GT01H/-GT02H/-GT04H/-GT08H/-GT10H/
-GT15H/-GT20H/-GT30H/-GT50H
Wiring Conforming to EMC Directives
Conformance to the EMC Directives (EN 55011 Class A Group 1 (EMI) and EN 61000-6-2 (EMS))
can be ensured by wiring under the conditions described below. These conditions are for
conformance of OMNUC G-Series products to the EMC Directives.
EMC-related performance of these products, however, depends on the configuration, wiring, and
other conditions of the equipment in which the products are installed. The EMC conformance of the
system as a whole must be confirmed by the customer.
The following are the requirements for EMC Directive conformance.
• The Servo Drive must be installed in a metal case (control panel). (The Servomotor does not,
• Noise filters and surge absorbers must be installed on power supply lines.
• Shielded cables must be used for all I/O signal lines and encoder lines. (Use tin-plated, mild steel
• All cables, I/O wiring, and power lines connected to the Servo Drive must have clamp filters
• The shields of all cables must be directly connected to a ground plate.
*1. For models with a single-phase power supply input (R88D-GTA5L/-GT01L/-GT02L/-GT04L/-
• Ground the motor's frame to the machine ground when the motor is on a movable shaft.
• Use a ground plate for the frame ground for each Unit, as shown in the above diagrams, and
• Use ground lines with a minimum thickness of 3.5 mm
however, have to be covered with a metal plate.)
wires for the shielding.)
installed.
ground to a single point.
lines are as short as possible.
GT01H/-GT02H/-GT04H/-GT08H), the main circuit power supply input terminals are L1 and L3.
SG
A
H
NF
F
E
B
TB Controller
FC
FC
G
L1
L2
L3
L1C
L2C
CNA
CN1
SV
CNB
CN2
2
, and arrange the wiring so that the ground
W
U
V
FC
FC
D
C
SM

Related parts for R88A-CNG02R