6-5 Trial Operation
Trial Operation in Speed Control Mode
Trial Operation in Torque Control Mode
6-29
1. Connect connector CN1.
2. Input power (12 to 24 VDC) for the control signals (+24VIN, COM).
3. Turn ON the power supply to the Servo Drive.
4. Confirm that the parameters are set to the standard settings.
5. Connect the RUN Command Input (RUN: CN1 pin 29) to COM (CN1 pin 41). Servo ON
6. Close the Zero-speed Designation Input (VZERO) and gradually increase the DC
7. Check the Servomotor rotation speed in Monitor Mode.
1. Connect connector CN1.
2. Input power (12 to 24 VDC) for the control signals (+24VIN, COM).
3. Turn ON the power supply to the Servo Drive.
4. Confirm that the parameters are set to the standard settings.
5. Set a low speed in the No. 4 Internally Set Speed (Pn56).
6. Connect the RUN Command Input (RUN: CN1 pin 29) to COM (CN1 pin 41). Servo ON
7. Apply a positive or negative DC voltage across the Torque Command Input (TREF1:
status will be entered and the Servomotor will be activated.
voltage across the Speed Command Input (REF: CN1 pin 14) and AGND (CN1 pin 15)
from 0 V. Check to see if the Servomotor rotates.
status will be entered and the Servomotor will be activated.
CN1 pin 14) and AGND (CN1 pin 15). Check to see if the Servomotor rotates
according to the direction (forward/reverse) set in Pn56.
Check to see if the Servomotor is rotating at the specified speed and to see if the Servomotor stops
when the command pulses are stopped. Use the following parameters to change the Servomotor
rotation speed or direction.
• Pn50: Speed Command Scale
• Pn51: Command Speed Rotation Direction Switch
Use the following parameters to change the amount of the torque, direction of the torque, or speed
limit for the command voltage.
• Pn56: No. 4 Internally Set Speed (default value: 50 r/min)
• Pn5C: Torque Command Scale
• Pn5D: Torque Output Direction Switch