MA180023 Microchip Technology, MA180023 Datasheet - Page 315

MODULE PLUG-IN PIC18F46J11 PIM

MA180023

Manufacturer Part Number
MA180023
Description
MODULE PLUG-IN PIC18F46J11 PIM
Manufacturer
Microchip Technology
Series
PIC®r
Datasheet

Specifications of MA180023

Accessory Type
Plug-In Module (PIM) - PIC18F46J11
Tool / Board Applications
General Purpose MCU, MPU, DSP, DSC
Mcu Supported Families
PIC18
Supported Devices
Stand-alone Or W/ HPC(DM183022) Or PIC18(DM183032)
Silicon Manufacturer
Microchip
Core Architecture
PIC
Core Sub-architecture
PIC18
Silicon Core Number
PIC18F
Silicon Family Name
PIC18FxxJxx
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
HPC Explorer Board (DM183022) or PIC18 Explorer Board (DM183032)
For Use With
DM183032 - BOARD EXPLORER PICDEM PIC18DM183022 - BOARD DEMO PIC18FXX22 64/80TQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MA180023
Manufacturer:
Microchip Technology
Quantity:
135
18.5.17.1
During a Start condition, a bus collision occurs if:
a)
b)
During a Start condition, both the SDAx and the SCLx
pins are monitored.
If the SDAx pin is already low, or the SCLx pin is
already low, then all of the following occur:
• The Start condition is aborted
• The BCLxIF flag is set
• The MSSP module is reset to its inactive state
The Start condition begins with the SDAx and SCLx
pins deasserted. When the SDAx pin is sampled high,
the BRG is loaded from SSPxADD<6:0> and counts
down to 0. If the SCLx pin is sampled low while SDAx
is high, a bus collision occurs because it is assumed
that another master is attempting to drive a data ‘1’
during the Start condition.
FIGURE 18-28:
© 2009 Microchip Technology Inc.
(Figure 18-28)
SDAx
SCLx
SEN
BCLxIF
S
SSPxIF
SDAx or SCLx is sampled low at the beginning
of the Start condition (Figure 18-28).
SCLx is sampled low before SDAx is asserted
low (Figure 18-29).
Bus Collision During a Start
Condition
condition if SDAx = 1, SCLx = 1
Set SEN, enable Start
BUS COLLISION DURING START CONDITION (SDAx ONLY)
SDAx sampled low before
Start condition. Set BCLxIF.
S bit and SSPxIF set because
SDAx = 0, SCLx = 1.
SDAx goes low before the SEN bit is set.
S bit and SSPxIF set because
SDAx = 0, SCLx = 1.
Set BCLxIF,
SSPxIF and BCLxIF are
cleared in software
PIC18F46J11 FAMILY
If the SDAx pin is sampled low during this count, the
BRG is reset and the SDAx line is asserted early
(Figure 18-30). If, however, a ‘1’ is sampled on the
SDAx pin, the SDAx pin is asserted low at the end of
the BRG count. The BRG is then reloaded and counts
down to 0. If the SCLx pin is sampled as ‘0’ during this
time, a bus collision does not occur. At the end of the
BRG count, the SCLx pin is asserted low.
Note:
SEN cleared automatically because of bus collision.
MSSPx module reset into Idle state.
The reason that bus collision is not a factor
during a Start condition is that no two bus
masters can assert a Start condition at the
exact same time. Therefore, one master
will always assert SDAx before the other.
This condition does not cause a bus colli-
sion because the two masters must be
allowed to arbitrate the first address
following the Start condition. If the address
is the same, arbitration must be allowed to
continue into the data portion, Repeated
Start or Stop conditions.
SSPxIF and BCLxIF are
cleared in software
DS39932C-page 315