ATA6613-EK Atmel, ATA6613-EK Datasheet - Page 176

no-image

ATA6613-EK

Manufacturer Part Number
ATA6613-EK
Description
BOARD DEMO LIN-MCM FOR ATA6613
Manufacturer
Atmel
Datasheets

Specifications of ATA6613-EK

Main Purpose
Interface, LIN + MCU
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
ATA6613
Primary Attributes
LIN-SBC (System-Basis-Chip) Transceiver, LIN 2.0, Voltage Regulator, Window Watchdog
Secondary Attributes
16 kB Flash, 4 Power Modes: Pre-Normal, Normal, Sleep, Silent, 48-QFN
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
176
Atmel ATA6612/ATA6613
Table 6-63
correct PWM mode.
Table 6-63.
Note:
Combined with the WGM22 bit found in the TCCR2B Register, these bits control the counting
sequence of the counter, the source for maximum (TOP) counter value, and what type of
waveform generation to be used, see
Timer/Counter unit are: Normal mode (counter), Clear Timer on Compare Match (CTC) mode,
and two types of Pulse Width Modulation (PWM) modes (see
168).
Table 6-64.
Notes:
• Bits 3, 2 – Res: Reserved Bits
• Bits 1:0 – WGM21:0: Waveform Generation Mode
Mode
COM2B1
0
1
2
3
4
5
6
7
These bits are reserved bits in the Atmel
zero.
0
0
1
1
1. A special case occurs when OCR2B equals TOP and COM2B1 is set. In this case, the Com-
1. MAX = 0xFF
2. BOTTOM = 0x00
WGM2
pare Match is ignored, but the set or clear is done at TOP. See
on page 171
shows the COM2B1:0 bit functionality when the WGM22:0 bits are set to phase
0
0
0
0
1
1
1
1
Compare Output Mode, Phase Correct PWM Mode
Waveform Generation Mode Bit Description
COM2B0
WGM1
0
1
0
1
0
0
1
1
0
0
1
1
for more details.
Description
Normal port operation, OC2B disconnected.
Reserved
Clear OC2B on Compare Match when up-counting. Set OC2B on
Compare Match when down-counting.
Set OC2B on Compare Match when up-counting. Clear OC2B on
Compare Match when down-counting.
WGM0
0
1
0
1
0
1
0
1
Timer/Counter
Mode of Operation
Normal
PWM, Phase
Correct
CTC
Fast PWM
Reserved
PWM, Phase
Correct
Reserved
Fast PWM
Table
®
6-64. Modes of operation supported by the
ATA6612/ATA6613 and will always read as
OCRA
OCRA
OCRA
0xFF
0xFF
0xFF
TOP
“Modes of Operation” on page
(1)
“Phase Correct PWM Mode”
Update of
Immediate
Immediate
OCRx at
TOP
TOP
TOP
TOP
9111H–AUTO–01/11
Set on
TOV Flag
BOTTOM
BOTTOM
MAX
MAX
MAX
TOP
(1)(2)

Related parts for ATA6613-EK