HD64F3684FP Renesas Electronics America, HD64F3684FP Datasheet - Page 314

IC H8 MCU FLASH 32K 64LQFP

HD64F3684FP

Manufacturer Part Number
HD64F3684FP
Description
IC H8 MCU FLASH 32K 64LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F3684FP

Core Processor
H8/300H
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, SCI
Peripherals
PWM, WDT
Number Of I /o
45
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
64-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3684FPI
Quantity:
2 761
Part Number:
HD64F3684FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3684FPV
Manufacturer:
RENESAS
Quantity:
28
Part Number:
HD64F3684FPV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 16 Serial Communication Interface 3 (SCI3)
16.4.4
Figure 16.7 shows an example of operation for reception in asynchronous mode. In serial
reception, the SCI3 operates as described below.
1. The SCI3 monitors the communication line. If a start bit is detected, the SCI3 performs
2. If an overrun error occurs (when reception of the next data is completed while the RDRF flag
3. If a parity error is detected, the PER bit in SSR is set to 1 and receive data is transferred to
4. If a framing error is detected (when the stop bit is 0), the FER bit in SSR is set to 1 and receive
5. If reception is completed successfully, the RDRF bit in SSR is set to 1, and receive data is
Table 16.6 shows the states of the SSR status flags and receive data handling when a receive error
is detected. If a receive error is detected, the RDRF flag retains its state before receiving data.
Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the OER,
Rev.5.00 Nov. 02, 2005 Page 280 of 500
REJ09B0027-0500
Serial
data
RDRF
FER
LSI
operation
User
processing
internal synchronization, receives receive data in RSR, and checks the parity bit and stop bit.
is still set to 1), the OER bit in SSR is set to 1. If the RIE bit in SCR3 is set to 1 at this time, an
ERI interrupt request is generated. Receive data is not transferred to RDR.
RDR. If the RIE bit in SCR3 is set to 1 at this time, an ERI interrupt request is generated.
data is transferred to RDR. If the RIE bit in SCR3 is set to 1 at this time, an ERI interrupt
request is generated.
transferred to RDR. If the RIE bit in SCR3 is set to 1 at this time, an RXI interrupt request is
generated. Continuous reception is possible because the RXI interrupt routine reads the receive
data transferred to RDR before reception of the next receive data has been completed.
Serial Data Reception
1
Start
bit
Figure 16.7 Example of SCI3 Reception in Asynchronous Mode
0
D0
D1
Receive
1 frame
data
(8-Bit Data, Parity, One Stop Bit)
D7
Parity
0/1
bit
RXI request
Stop
bit
1
Start
bit
0
D0
RDRF
cleared to 0
RDR data read
1 frame
D1
Receive
data
D7
Parity
0/1
bit
Stop
bit
0
0 stop bit
detected
Mark state
(idle state)
1
ERI request in
response to
framing error
Framing error
processing