PNX1501E NXP Semiconductors, PNX1501E Datasheet - Page 764

no-image

PNX1501E

Manufacturer Part Number
PNX1501E
Description
Digital Signal Processors & Controllers (DSP, DSC) MEDIA PROCESSOR PNX15XX/266MHZ
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PNX1501E

Product
DSPs
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
SOT-795
Minimum Operating Temperature
0 C
Lead Free Status / Rohs Status
 Details
Other names
PNX1501E,557

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PNX1501E
Manufacturer:
PHILIPS
Quantity:
5
Part Number:
PNX1501E,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
PNX1501E/G
Manufacturer:
NXP Semiconductors
Quantity:
135
Part Number:
PNX1501E/G
Manufacturer:
MICROCHIP
Quantity:
12 000
Part Number:
PNX1501E/G
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Philips Semiconductors
Volume 1 of 1
Table 5: Status Codes
12NC 9397 750 14321
Product data sheet
Status
Code
STA
0x88
0x90
0x98
Bus/Module
Status
Previously
addressed with
own SLA; data
byte has been
received; NOT
ACK has been
returned
Previously
addressed with
general call; data
byte has been
received; ACK has
been returned
Previously
addressed with
general call; data
byte has been
received; NOT
ACK has been
returned
…Continued
Application Software Response
To/From DAT
Read data
byte
Read data
byte
Read data
byte
Read data
byte
Read data
byte
Read data
byte
Read data
byte
Read data
byte
Read data
byte
Read data
byte
To CON
STA
0
0
1
1
X
X
0
0
1
1
Rev. 2 — 1 December 2004
STO
0
0
0
0
0
0
0
0
0
0
SI
0
0
0
0
0
0
0
0
0
0
AA
0
1
0
1
0
1
0
1
0
1
Next Action Taken
Switched to “not addressed” SLV mode; no
recognition of own SLA or general call
address.
Switched to “not addressed” SLV mode;
own SLA will be recognized; general call
address will be recognized if ADR(0) =’1’.
Switched to “not addressed” SLV mode; no
recognition of own SLA or general call
address. A START condition will be
transmitted when bus becomes free.
Switched to “not addressed” SLV mode;
own SLA will be recognized; general call
address will be recognized if ADR(0) =’1’; A
START condition will be transmitted when
the bus becomes free.
Data byte will be received and NOT ACK
will be returned.
Data byte will be received and ACK will be
returned.
Switched to “not addressed” SLV mode; no
recognition of own SLA or general call
address.
Switched to “not addressed” SLV mode;
Own SLA will be recognized; general call
address will be recognized if ADR(0) =’1’.
Switched to “not addressed” SLV mode; no
recognition of own SLA or general call
address. A START condition will be
transmitted when the bus becomes free.
Switched to “not addressed” SLV mode;
own SLA will be recognized; general call
address will be recognized if ADR(0) =’1’; A
START condition will be transmitted when
the bus becomes free.
© Koninklijke Philips Electronics N.V. 2002-2003-2004. All rights reserved.
PNX15xx Series
Chapter 25: I
2
C Interface
25-14

Related parts for PNX1501E