DF3048BVX25V Renesas Electronics America, DF3048BVX25V Datasheet - Page 532

MCU 3/5V 128K PB-FREE 100-TQFP

DF3048BVX25V

Manufacturer Part Number
DF3048BVX25V
Description
MCU 3/5V 128K PB-FREE 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheets

Specifications of DF3048BVX25V

Core Processor
H8/300H
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
70
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF3048BVX25V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 13 Serial Communication Interface
Receiving Serial Data: Figure 13.18 shows a sample flowchart for receiving serial data and
indicates the procedure to follow. When switching from asynchronous mode to synchronous
mode, make sure that the ORER, PER, and FER flags are cleared to 0. If the FER or PER flag is
set to 1 the RDRF flag will not be set and both transmitting and receiving will be disabled.
Rev. 3.00 Sep 27, 2006 page 504 of 872
REJ09B0325-0300
No
No
Read ORER flag in SSR
Clear RE bit to 0 in SCR
Read RDRF flag in SSR
RDRF flag to 0 in SSR
from RDR, and clear
Read receive data
Start receiving
ORER = 1?
RDRF = 1?
receiving?
Finished
Initialize
End
Figure 13.18 Sample Flowchart for Serial Receiving (1)
Yes
Yes
No
continued on next page
Yes
Error handling
1
2
4
5
3
1.
2, 3.
4.
5.
SCI initialization: the receive data function of
the RxD pin is selected automatically.
occurs, read the ORER flag in SSR, then after
executing the necessary error handling, clear
the ORER flag to 0. Neither transmitting nor
receiving can resume while the ORER flag
remains set to 1.
SCI status check and receive data read: read
SSR, check that the RDRF flag is set to 1,
then read receive data from RDR and clear
the RDRF flag to 0. Notification that the RDRF
flag has changed from 0 to 1 can also be
given by the RXI interrupt.
To continue receiving serial data: check the
RDRF flag, read RDR, and clear the RDRF
flag to 0 before the MSB (bit 7) of the current
frame is received. If the DMAC is activated
by a receive-data-full interrupt request (RXI)
to read RDR, the RDRF flag is cleared
automatically.
Receive error handling: if a receive error

Related parts for DF3048BVX25V