SI4431-A0-FM Silicon Laboratories Inc, SI4431-A0-FM Datasheet - Page 133

IC TXRX ISM 930MHZ 3.6V 20-QFN

SI4431-A0-FM

Manufacturer Part Number
SI4431-A0-FM
Description
IC TXRX ISM 930MHZ 3.6V 20-QFN
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI4431-A0-FM

Package / Case
20-QFN
Mfg Application Notes
Transitioning SI4430/31 to Rev B
Frequency
240MHz ~ 930MHz
Data Rate - Maximum
128kbps
Modulation Or Protocol
FSK, GFSK, OOK
Power - Output
13dBm
Sensitivity
-118dBm
Voltage - Supply
1.8 V ~ 3.6 V
Current - Receiving
18.5mA
Current - Transmitting
28mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Number Of Receivers
2
Number Of Transmitters
1
Wireless Frequency
240 MHz to 930 MHz
Output Power
13 dBm
Operating Supply Voltage
1.8 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Maximum Supply Current
28 mA
Minimum Operating Temperature
- 40 C
Modulation
FSK, GFSK, OOK
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
336-1633-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI4431-A0-FMR
Manufacturer:
SILICON
Quantity:
3 500
Part Number:
SI4431-A0-FMR
Manufacturer:
SILICONLABS/芯科
Quantity:
20 000
Company:
Part Number:
SI4431-A0-FMR
Quantity:
13 293
Register 55h. Calibration Control
Reset value = x1x00100
Name
Type
Bit
Bit
7
6
5
4
3
2
1
0
Reserved
adccaldone
xtalstarthalf
Reserved
vcocaldp
enrcfcal
skipvco
Name
vcocal
D7
rccal
R
xtalstarthalf
Reserved.
If Set, the Xtal Wake Time Period is Halved.
Delta-sigma ADC Calibration Done. Reading this bit gives 1 if the calibration process
has been finished.
RC Oscillator Fine Calibration Enable.
If this bit is set to 1 then the RC oscillator performs fine calibration in every app. 30 s.
RC Calibration Force.
If setting rccal = 1 will automatically perform a forced calibration of the 32 kHz RC Oscil-
lator. The RC OSC will automatically be calibrated if the Wake-Up-Timer is enabled or if
in the Wake-on-Receiver state. The calibration takes 2 ms. The 32 kHz RC oscillator
must be enabled to perform a calibration. Setting this signal from a 0 to 1 will initiate the
calibration. This bit is cleared automatically.
VCO Calibration Double Precision Enable.
When this bit is set to 1 then the VCO calibration measures longer thus calibrates more
precisely.
VCO Calibration Force.
If in Idle Mode and pllon = 1, setting vcocal = 1 will force a one time calibration of the syn-
thesizer VCO. This bit is cleared automatically.
Skip VCO Calibration.
Setting skipvco = 1 will skip the VCO calibration when going from the Idle state to the TX
or RX state.
R/W
D6
adccaldone
D5
R
Preliminary Rev. 0.4
enrcfcal
R/W
D4
Function
rccal
R/W
D3
vcocaldp
R/W
D2
vcocal
R/W
D1
Si4431
skipvco
R/W
D0
133