mcf5282 Freescale Semiconductor, Inc, mcf5282 Datasheet - Page 185

no-image

mcf5282

Manufacturer Part Number
mcf5282
Description
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCF5282
Manufacturer:
MOTOLOLA
Quantity:
648
Part Number:
mcf5282CVF66
Manufacturer:
FREESCAL
Quantity:
600
Part Number:
mcf5282CVF66
Manufacturer:
FREESCALE
Quantity:
2
Part Number:
mcf5282CVF66
Manufacturer:
FREESCAL
Quantity:
152
Part Number:
mcf5282CVF66
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mcf5282CVF66
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
mcf5282CVF66J
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mcf5282CVF80
Manufacturer:
FREESCALE
Quantity:
12 388
Part Number:
mcf5282CVF80
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mcf5282CVF80J
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mcf5282CVM66
Manufacturer:
FREESCALE
Quantity:
1 002
Part Number:
mcf5282CVM66
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
mcf5282CVM80
Quantity:
4
9.7.4.7
If the LOLRE bit in the SYNCR is set, a loss of lock condition asserts reset. Reset reinitializes the LOCK
and LOCKS flags. Therefore, software must read the LOL bit in the reset status register (RSR) to
determine if a loss of lock caused the reset. See
To exit reset in PLL mode, the reference must be present, and the PLL must achieve lock.
In external clock mode, the PLL cannot lock. Therefore, a loss of lock condition cannot occur, and the
LOLRE bit has no effect.
9.7.4.8
The LOCEN bit in the SYNCR enables the loss of clock detection circuit to monitor the input clocks to
the phase and frequency detector (PFD). When either the reference or feedback clock frequency falls
below the minimum frequency, the loss of clock circuit sets the sticky LOCS flag in the SYNSR.
9.7.4.9
The clock module can assert a reset when a loss of clock or loss of lock occurs. When a loss-of-clock
condition is recognized, reset is asserted if the LOCRE bit in SYNCR is set. The LOCS bit in SYNSR is
cleared after reset. Therefore, the LOC bit must be read in RSR to determine that a loss of clock condition
occurred. LOCRE has no effect in external clock mode.
To exit reset in PLL mode, the reference must be present, and the PLL must acquire lock.
Reset initializes the clock module registers to a known startup state as described in
Map and
9.7.4.10 Alternate Clock Selection
Depending on which clock source fails, the loss-of-clock circuit switches the system clocks source to the
remaining operational clock. The alternate clock source generates the system clocks until reset is asserted.
As
The PLL remains in SCM until the next reset. When the PLL is operating in SCM, the system frequency
depends on the value in the RFD field. The SCM system frequency stated in electrical specifications
assumes that the RFD has been programmed to binary 000. If the loss-of-clock condition is due to PLL
failure, the PLL reference becomes the system clocks source until the next reset, even if the PLL regains
and relocks.
Freescale Semiconductor
1
Table 9-9
The LOC circuit monitors the reference and feedback inputs to the PFD. See
External
Clock
Mode
PLL
Registers.”
PLL Loss of Lock Reset
Loss of Clock Detection
Loss of Clock Reset
shows, if the reference fails, the PLL goes out of lock and into self-clocked mode (SCM).
In external clock mode, the loss of clock circuit is disabled.
System Clock Source
Before Failure
External clock
PLL
MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3
Table 9-9. Loss of Clock Summary
Selected by LOC Circuit
Reference Failure Alternate Clock
PLL self-clocked mode
Section 29.4.2, “Reset Status Register
NOTE
None
1
Until Reset
Figure
Selected by LOC Circuit Until Reset
PLL Failure Alternate Clock
9-5.
PLL reference
Section 9.6, “Memory
NA
(RSR).”
Clock Module
9-15