mcf5282 Freescale Semiconductor, Inc, mcf5282 Datasheet - Page 477

no-image

mcf5282

Manufacturer Part Number
mcf5282
Description
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCF5282
Manufacturer:
MOTOLOLA
Quantity:
648
Part Number:
mcf5282CVF66
Manufacturer:
FREESCAL
Quantity:
600
Part Number:
mcf5282CVF66
Manufacturer:
FREESCALE
Quantity:
2
Part Number:
mcf5282CVF66
Manufacturer:
FREESCAL
Quantity:
152
Part Number:
mcf5282CVF66
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mcf5282CVF66
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
mcf5282CVF66J
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mcf5282CVF80
Manufacturer:
FREESCALE
Quantity:
12 388
Part Number:
mcf5282CVF80
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mcf5282CVF80J
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mcf5282CVM66
Manufacturer:
FREESCALE
Quantity:
1 002
Part Number:
mcf5282CVM66
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
mcf5282CVM80
Quantity:
4
25.3.1.2 Fields for Extended Format Frames
Table 25-5
25.3.1.3 Fields for Standard Format Frames
Table 25-6
25.3.2
The message buffer memory map starts at an offset of 0x80 from the FlexCAN’s base address
(0x1C_0000). The 256-byte message buffer space is fully used by the 16 message buffer structures.
Freescale Semiconductor
ID[28:18]/[17:15] Contains the 14 most significant bits of the extended identifier, located in the ID HIGH word of the
Remote Request
Request (RTR)
Transmission
ID Extended
16-Bit Time
Substitute
ID[28:18]
ID[14:0]
Remote
(SRR)
Stamp
Field
(IDE)
Field
RTR
describes the message buffer fields used only for extended identifier format frames.
describes the message buffer fields used only for standard identifier format frames.
Message Buffer Memory Map
message buffer.
Contains a fixed recessive bit, used only in extended format. Should be set to one by the user for
Tx buffers. It will be stored as received on the CAN bus for Rx buffers. This is a bit in the ID HIGH
word of the message buffer.
If extended format frame is used, this field should be set to one. If zero, standard format frame
should be used. This is a bit in the ID HIGH word of the message buffer.
This bit is located in the least significant bit of the ID LOW word of the message buffer;
0 Data Frame
1 Remote Frame.
Bits [14:0] of the extended identifier, located in the ID LOW word of the message buffer.
Contains bits [28:18] of the identifier, located in the ID HIGH word of the message buffer. The four
least significant bits in this register (corresponding to the IDE bit and ID[17:15] for an extended
identifier message) must all be written as logic zeros to ensure proper operation of the FlexCAN.
Remote Transmission Request. This bit is located in the ID HIGH word of the message buffer.
0 data frame
1 remote frame.
If the FlexCAN transmits this bit as a one and receives it as a zero, an “arbitration loss” is
indicated. If the FlexCAN transmits this bit as a zero and receives it as a one, a bit error is
indicated.
If the FlexCAN transmits a value and receives a matching response, a successful bit transmission
is indicated.
The 16-bit time stamp, located in the ID LOW word of the message buffer, is not needed for
standard format, and is used in a standard format buffer to store the 16-bit value of the
free-running timer. The timer value is captured at the beginning of the identifier field of the frame
on the CAN bus.
MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3
Table 25-5. Extended Format Frames
Table 25-6. Standard Format Frames
Description
Description
FlexCAN
25-7