S912XET256J2VAGR Freescale Semiconductor, S912XET256J2VAGR Datasheet - Page 470

no-image

S912XET256J2VAGR

Manufacturer Part Number
S912XET256J2VAGR
Description
16-bit Microcontrollers - MCU Watchdog OSC/Timer -40 C to + 105 C HCS12X MCU SPI
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S912XET256J2VAGR

Core
HCS12X
Data Bus Width
16 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
256 KB
Data Ram Size
16 KB
On-chip Adc
Yes
Package / Case
LQFP
Mounting Style
SMD/SMT
A/d Bit Size
12 bit
A/d Channels Available
24
Interface Type
CAN, SCI, SPI
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
119
Number Of Timers
25
Program Memory Type
Flash
Supply Voltage - Max
1.98 V, 2.9 V, 5.5 V
Supply Voltage - Min
1.72 V, 2.7 V, 3.13 V
Chapter 11 S12XE Clocks and Reset Generator (S12XECRGV1)
11.1.2
This subsection lists and briefly describes all operating modes supported by the S12XECRG.
11.1.3
Figure 11-1
470
— Illegal address reset
— COP reset
— Loss of clock reset
— External pin reset
Real-Time Interrupt (RTI)
Run Mode
All functional parts of the S12XECRG are running during normal Run Mode. If RTI or COP
functionality is required the individual bits of the associated rate select registers (COPCTL,
RTICTL) have to be set to a non zero value.
Wait Mode
In this mode the IPLL can be disabled automatically depending on the PLLWAI bit.
Stop Mode
Depending on the setting of the PSTP bit Stop Mode can be differentiated between Full Stop Mode
(PSTP = 0) and Pseudo Stop Mode (PSTP = 1).
— Full Stop Mode
— Pseudo Stop Mode
Self Clock Mode
Self Clock Mode will be entered if the Clock Monitor Enable Bit (CME) and the Self Clock Mode
Enable Bit (SCME) are both asserted and the clock monitor in the oscillator block detects a loss of
clock. As soon as Self Clock Mode is entered the S12XECRG starts to perform a clock quality
check. Self Clock Mode remains active until the clock quality check indicates that the required
quality of the incoming clock signal is met (frequency and amplitude). Self Clock Mode should be
used for safety purposes only. It provides reduced functionality to the MCU in case a loss of clock
is causing severe system conditions.
The oscillator is disabled and thus all system and core clocks are stopped. The COP and the
RTI remain frozen.
The oscillator continues to run and most of the system and core clocks are stopped. If the
respective enable bits are set the COP and RTI will continue to run, else they remain frozen.
Modes of Operation
Block Diagram
shows a block diagram of the S12XECRG.
MC9S12XE-Family Reference Manual Rev. 1.25
Freescale Semiconductor

Related parts for S912XET256J2VAGR