7.7.14
Name:
Access Type:
Offset:
Reset Value:
• AE: Access Error
• CKRDY: Clock Ready
• CFD: Clock Failure Detected
9166C–AVR-08/11
AE
31
23
15
7
-
-
-
0: No access error has occured.
1: A write to lock protected register without unlocking it has occured.
0: The CKSEL register has been written, and the new clock setting is not yet effective.
1: The synchronous clocks have frequencies as indicated in the CKSEL register.
0: Main clock is running correctly.
1: Failure on main clock detected. Main clock is now running on RC osc.
Status Register
30
22
14
6
-
-
-
-
SR
Read-only
0x0D4
0x00000000
CKRDY
29
21
13
5
-
-
-
28
20
12
4
-
-
-
-
27
19
11
3
-
-
-
-
26
18
10
2
-
-
-
-
25
17
9
1
-
-
-
-
AT32UC3C
CFD
24
16
8
0
-
-
-