MC9S12P32CFT Freescale Semiconductor, MC9S12P32CFT Datasheet - Page 387

no-image

MC9S12P32CFT

Manufacturer Part Number
MC9S12P32CFT
Description
MCU 16BIT 32K FLASH 48-QFN
Manufacturer
Freescale Semiconductor
Series
HCS12r
Datasheet

Specifications of MC9S12P32CFT

Core Processor
HCS12
Core Size
16-Bit
Speed
32MHz
Connectivity
CAN, SCI, SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
34
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Eeprom Size
4K x 8
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
1.72 V ~ 5.5 V
Data Converters
A/D 10x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
48-QFN Exposed Pad
Processor Series
S12P
Core
HCS12
3rd Party Development Tools
EWHCS12
Development Tools By Supplier
KIT33812ECUEVME, DEMO9S12PFAME
Package
48QFN EP
Family Name
HCS12
Maximum Speed
32 MHz
Operating Supply Voltage
3.3|5 V
Data Bus Width
16 Bit
Interface Type
CAN/SCI/SPI
On-chip Adc
10-chx12-bit
Number Of Timers
8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
indicating that the received byte can be read. If the receive interrupt enable bit, RIE, in SCI control
register 2 (SCICR2) is also set, the RDRF flag generates an RDRF interrupt request.
11.4.6.3
The RT clock rate. The RT clock is an internal signal with a frequency 16 times the baud rate. To adjust
for baud rate mismatch, the RT clock (see
To locate the start bit, data recovery logic does an asynchronous search for a logic 0 preceded by three logic
1s.When the falling edge of a possible start bit occurs, the RT clock begins to count to 16.
To verify the start bit and to detect noise, data recovery logic takes samples at RT3, RT5, and RT7.
Figure 11-17
If start bit verification is not successful, the RT clock is reset and a new search for a start bit begins.
Freescale Semiconductor
RT CLock Count
Reset RT Clock
After every start bit
After the receiver detects a data bit change from logic 1 to logic 0 (after the majority of data bit
samples at RT8, RT9, and RT10 returns a valid logic 1 and the majority of the next RT8, RT9, and
RT10 samples returns a valid logic 0)
RT Clock
Samples
RXD
Data Sampling
summarizes the results of the start bit verification samples.
1
RT3, RT5, and RT7 Samples
1
1
1
000
001
010
011
100
101
110
111
1
1
Figure 11-21. Receiver Data Sampling
S12P-Family Reference Manual, Rev. 1.13
Qualification
Start Bit
Table 11-17. Start Bit Verification
1
1
Figure
0
0
11-21) is re-synchronized:
Start Bit Verification
Verification
Start Bit
0
Yes
Yes
Yes
Yes
No
No
No
No
0
Start Bit
0
Sampling
Data
0
0
Serial Communication Interface (S12SCIV5)
Noise Flag
0
1
1
0
1
0
0
0
LSB
387

Related parts for MC9S12P32CFT