s3c4510b Samsung Semiconductor, Inc., s3c4510b Datasheet - Page 212

no-image

s3c4510b

Manufacturer Part Number
s3c4510b
Description
16/32-bit Risc Microcontroller
Manufacturer
Samsung Semiconductor, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
s3c4510b01-QE80
Manufacturer:
BOURNS
Quantity:
400 000
Part Number:
s3c4510b01-QE80
Manufacturer:
SUNMNG
Quantity:
853
Part Number:
s3c4510b01-QE80
Manufacturer:
SAMSUNG
Quantity:
8 000
Part Number:
s3c4510b01-QER0
Manufacturer:
AMCC
Quantity:
156
Part Number:
s3c4510b01-QER0
Manufacturer:
SAMSUMG
Quantity:
20 000
Company:
Part Number:
s3c4510b01-QER0
Quantity:
58
Part Number:
s3c4510b01-QERO
Manufacturer:
Panasonic
Quantity:
12 000
Part Number:
s3c4510b01-QERO
Manufacturer:
SAMSUNG
Quantity:
16 615
2
I
C BUS CONTROLLER
S3C4510B
FUNCTIONAL DESCRIPTION
2
2
The S3C4510B I
C bus controller is the master of the serial I
C-bus. Using a prescaler register, you can program
2
the serial clock frequency that is supplied to the I
C bus controller. The serial clock frequency is calculated as
follows:
MCLK / (16
(prescaler register value + 1) + 3)
2
To initialize the serial I
C-bus, the programmer sends a start code by writing "01" to bits [5:4]of the control status
register, IICCON. The bus controller then sends the 7-bit slave address and a read/write control bit through shift
buffer register. The receiver sends an acknowledge by pulling the SDA line from high to low during a master SCL
pulse.
To continue the data write operation, you must set the BF bit in the control status register and then write the data
to the shift buffer register. Whenever the shift buffer register is read or written, the BF bit is cleared
automatically. For the consecutive read/write operations, you must set the ACK bit in the control status register.
For read operations, you can read the data after you have set the BF bit in the control status register. To signal
the end of the read operation, you can reset the ACK bit to inform the receiver/transmitter when the last byte is to
be written/read.
Following a read/write operation, you set IICCON[5:4] to "10" to generate a stop code. If you want to complete
another data transfer before issuing the Stop code, you can send the start code using the repeat start command
(with IICCON[5:4] = "11"). When the slave address and read/write control bit have been sent, and when the
receive acknowledge has been issued to control SCL timing, the data transfer is initiated.
6-2