SAM3U1C Atmel Corporation, SAM3U1C Datasheet - Page 289

no-image

SAM3U1C

Manufacturer Part Number
SAM3U1C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3U1C

Flash (kbytes)
64 Kbytes
Pin Count
100
Max. Operating Frequency
96 MHz
Cpu
Cortex-M3
# Of Touch Channels
28
Hardware Qtouch Acquisition
No
Max I/o Pins
57
Ext Interrupts
57
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Hi-Speed
Usb Interface
Device
Spi
4
Twi (i2c)
1
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
20
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
Figure 19-4. Supply Monitor Status Bit and Associated Interrupt
6430E–ATARM–29-Aug-11
6430E–ATARM–29-Aug-11
SMS and SUPC interrupt
Supply Monitor ON
Threshold
A supply monitor detection can either generate a reset of the core power supply or a wake up of
the core power supply. Generating a core reset when a supply monitor detection occurs is
enabled by writing the SMRSTEN bit to 1 in SUPC_SMMR.
Waking up the core power supply when a supply monitor detection occurs can be enabled by
programming the SMEN bit to 1 in the Supply Controller Wake Up Mode Register
(SUPC_WUMR).
The Supply Controller provides two status bits in the Supply Controller Status Register for the
supply monitor which allows to determine whether the last wake up was due to the supply
monitor:
The SMS bit can generate an interrupt if the SMIEN bit is set to 1 in the Supply Controller Supply
Monitor Mode Register (SUPC_SMMR).
3.3 V
• The SMOS bit provides real time information, which is updated at each measurement cycle
• The SMS bit provides saved information and shows a supply monitor detection has occurred
0 V
or updated at each Slow Clock cycle, if the measurement is continuous.
since the last read of SUPC_SR.
Read SUPC_SR
Continuous Sampling (SMSMPL = 1)
Periodic Sampling
SAM3U Series
SAM3U Series
289
289