SAM3U1C Atmel Corporation, SAM3U1C Datasheet - Page 673

no-image

SAM3U1C

Manufacturer Part Number
SAM3U1C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3U1C

Flash (kbytes)
64 Kbytes
Pin Count
100
Max. Operating Frequency
96 MHz
Cpu
Cortex-M3
# Of Touch Channels
28
Hardware Qtouch Acquisition
No
Max I/o Pins
57
Ext Interrupts
57
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Hi-Speed
Usb Interface
Device
Spi
4
Twi (i2c)
1
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
20
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
Figure 34-5. Receiver Ready
34.5.2.4
Figure 34-6. Receiver Overrun
34.5.2.5
Figure 34-7. Parity Error
34.5.2.6
6430E–ATARM–29-Aug-11
6430E–ATARM–29-Aug-11
RXRDY
URXD
RXRDY
OVRE
URXD
RXRDY
URXD
PARE
S
S
Receiver Overrun
Parity Error
Receiver Framing Error
D0
D0
S
D1
D1
D0
D2
D2
If UART_RHR has not been read by the software (or the Peripheral Data Controller or DMA
Controller) since the last transfer, the RXRDY bit is still set and a new character is received, the
OVRE status bit in UART_SR is set. OVRE is cleared when the software writes the control regis-
ter UART_CR with the bit RSTSTA (Reset Status) at 1.
Each time a character is received, the receiver calculates the parity of the received data bits, in
accordance with the field PAR in UART_MR. It then compares the result with the received parity
bit. If different, the parity error bit PARE in UART_SR is set at the same time the RXRDY is set.
The parity bit is cleared when the control register UART_CR is written with the bit RSTSTA
(Reset Status) at 1. If a new character is received before the reset status command is written,
the PARE bit remains at 1.
When a start bit is detected, it generates a character reception when all the data bits have been
sampled. The stop bit is also sampled and when it is detected at 0, the FRAME (Framing Error)
bit in UART_SR is set at the same time the RXRDY bit is set. The FRAME bit remains high until
the control register UART_CR is written with the bit RSTSTA at 1.
D1
D3
D3
D2
D4
D4
D3
D5
D5
D4
D6
D6
D5
D7
D7
D6
P
Wrong Parity Bit
P
D7
stop
P
S
S
stop
D0
Read UART_RHR
D0
D1
D1
D2
D2
D3
RSTSTA
D3
D4
D4
D5
D5
SAM3U Series
SAM3U Series
D6
D6
D7
D7
P
P
stop
RSTSTA
673
673

Related parts for SAM3U1C