SAM3U1C Atmel Corporation, SAM3U1C Datasheet - Page 696

no-image

SAM3U1C

Manufacturer Part Number
SAM3U1C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3U1C

Flash (kbytes)
64 Kbytes
Pin Count
100
Max. Operating Frequency
96 MHz
Cpu
Cortex-M3
# Of Touch Channels
28
Hardware Qtouch Acquisition
No
Max I/o Pins
57
Ext Interrupts
57
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Hi-Speed
Usb Interface
Device
Spi
4
Twi (i2c)
1
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
20
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
35.7.1
35.7.1.1
696
696
SAM3U Series
SAM3U Series
Baud Rate Generator
Baud Rate in Asynchronous Mode
The Baud Rate Generator provides the bit period clock named the Baud Rate Clock to both the
receiver and the transmitter.
The Baud Rate Generator clock source can be selected by setting the USCLKS field in the Mode
Register (US_MR) between:
The Baud Rate Generator is based upon a 16-bit divider, which is programmed with the CD field
of the Baud Rate Generator Register (US_BRGR). If CD is programmed to 0, the Baud Rate
Generator does not generate any clock. If CD is programmed to 1, the divider is bypassed and
becomes inactive.
If the external SCK clock is selected, the duration of the low and high levels of the signal pro-
vided on the SCK pin must be longer than a Master Clock (MCK) period. The frequency of the
signal provided on SCK must be at least 3 times lower than MCK in USART mode, or 6 in SPI
mode.
Figure 35-3. Baud Rate Generator
If the USART is programmed to operate in asynchronous mode, the selected clock is first
divided by CD, which is field programmed in the Baud Rate Generator Register (US_BRGR).
The resulting clock is provided to the receiver as a sampling clock and then divided by 16 or 8,
depending on the programming of the OVER bit in US_MR.
If OVER is set to 1, the receiver sampling is 8 times higher than the baud rate clock. If OVER is
cleared, the sampling is performed at 16 times the baud rate clock.
The following formula performs the calculation of the Baud Rate.
• the Master Clock MCK
• a division of the Master Clock, the divider being product dependent, but generally set to 8
• the external clock, available on the SCK pin
SCK
Reserved
MCK/DIV
MCK
USCLKS
0
1
2
3
16-bit Counter
CD
USCLKS = 3
0
SYNC
CD
>1
1
0
1
0
OVER
Sampling
Divider
FIDI
6430E–ATARM–29-Aug-11
6430E–ATARM–29-Aug-11
0
1
SYNC
SCK
Baud Rate
Sampling
Clock
Clock