SAM3U1C Atmel Corporation, SAM3U1C Datasheet - Page 302

no-image

SAM3U1C

Manufacturer Part Number
SAM3U1C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3U1C

Flash (kbytes)
64 Kbytes
Pin Count
100
Max. Operating Frequency
96 MHz
Cpu
Cortex-M3
# Of Touch Channels
28
Hardware Qtouch Acquisition
No
Max I/o Pins
57
Ext Interrupts
57
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Hi-Speed
Usb Interface
Device
Spi
4
Twi (i2c)
1
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
20
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
19.5.8
Name:
Address:
Access:
Note:
• FWUPS: FWUP Wake Up Status
0 (NO) = no wake up due to the assertion of the FWUP pin has occurred since the last read of SUPC_SR.
1 (PRESENT) = at least one wake up due to the assertion of the FWUP pin has occurred since the last read of SUPC_SR.
• WKUPS: WKUP Wake Up Status
0 (NO) = no wake up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR.
1 (PRESENT) = at least one wake up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR.
• SMWS: Supply Monitor Detection Wake Up Status
0 (NO) = no wake up due to a supply monitor detection has occurred since the last read of SUPC_SR.
1 (PRESENT) = at least one wake up due to a supply monitor detection has occurred since the last read of SUPC_SR.
• BODRSTS: Brownout Detector Reset Status
0 (NO) = no core brownout rising edge event has been detected since the last read of the SUPC_SR.
1 (PRESENT) = at least one brownout output rising edge event has been detected since the last read of the SUPC_SR.
When the voltage remains below the defined threshold, there is no rising edge event at the output of the brownout detec-
tion cell. The rising edge event occurs only when there is a voltage transition below the threshold.
• SMRSTS: Supply Monitor Reset Status
0 (NO) = no supply monitor detection has generated a core reset since the last read of the SUPC_SR.
1 (PRESENT) = at least one supply monitor detection has generated a core reset since the last read of the SUPC_SR.
• SMS: Supply Monitor Status
0 (NO) = no supply monitor detection since the last read of SUPC_SR.
1 (PRESENT) = at least one supply monitor detection since the last read of SUPC_SR.
302
302
WKUPIS15
WKUPIS7
OSCSEL
31
23
15
7
Because of the asynchronism between the Slow Clock (SCLK) and the System Clock (MCK), the status register flag reset is
taken into account only 2 slow clock cycles after the read of the SUPC_SR.
SAM3U Series
SAM3U Series
Supply Controller Status Register
SUPC_SR
0x400E1224
Read-write
WKUPIS14
WKUPIS6
SMOS
30
22
14
6
WKUPIS13
WKUPIS5
SMS
29
21
13
5
WKUPIS12
WKUPIS4
SMRSTS
FWUPIS
28
20
12
4
WKUPIS11
BODRSTS
WKUPIS3
27
19
11
3
WKUPIS10
WKUPIS2
SMWS
26
18
10
2
WKUPIS9
WKUPIS1
WKUPS
25
17
9
1
6430E–ATARM–29-Aug-11
6430E–ATARM–29-Aug-11
WKUPIS8
WKUPIS0
FWUPS
24
16
8
0

Related parts for SAM3U1C