Real-Time Clock Minutes Register
This register contains the current minutes count. The value in the RTC_MIN regis-
ter is unchanged by a RESET. The current setting of BCD_EN determines
whether the values in this register are binary (BCD_EN = 0) or binary-coded deci-
mal (BCD_EN = 1). Access to this register is Read Only if the RTC is locked and
Read/Write if the RTC is unlocked. See Table 81.
Table 81. Real-Time Clock Minutes Register
(RTC_MIN = 00E1h)
Bit
Reset
CPU Access
Note: X = Unchanged by RESET; R/W* = Read Only if RTC locked, Read/Write if RTC unlocked.
Binary-Coded-Decimal Operation (BCD_EN = 1)
Bit
Position
[7:4]
TEN_MIN
[3:0]
MIN
Binary Operation (BCD_EN = 0)
Bit
Position
[7:0]
MIN
Value Description
0–5
0–9
Value Description
00h–
3Bh
R/W*
The tens digit of the current minutes count.
The ones digit of the current minutes count.
The current minutes count.
P R E L I M I N A R Y
X
7
R/W*
6
X
R/W*
X
5
R/W*
X
4
R/W*
X
3
Product Specification
R/W*
X
2
eZ80F91 MCU
Real-Time Clock
R/W*
X
1
R/W*
X
0