PEB20571 INFINEON [Infineon Technologies AG], PEB20571 Datasheet - Page 73

no-image

PEB20571

Manufacturer Part Number
PEB20571
Description
ICs for Communications
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB20571F
Manufacturer:
INFINEON
Quantity:
17
Part Number:
PEB20571F
Manufacturer:
PULSE
Quantity:
23 900
Part Number:
PEB20571F V3.1
Manufacturer:
Infineon
Quantity:
748
Part Number:
PEB20571FV3.1
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
PEB20571FV3.1
Manufacturer:
INF
Quantity:
5 510
Part Number:
PEB20571FV3.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
PEB20571FV3.1
Quantity:
22
LT-S Mode States
• G1 deactivated
• G2 pending activation
• G3 activated
• G2 lost framing
• G4 pending deactivation
• G4 wait for DR
• Test mode 1
• Test mode 2
Preliminary Data Sheet
The line interface is not transmitting. There is no signal detected on the S interface,
and no activation command is received.
As a result of an INFO 1 detected on the S line or an AR command, the line interface
begins transmitting INFO 2 and waits for reception of INFO 3. The timer to supervise
reception of INFO 3 is to be implemented in software. In case of an ARL command,
loop 2 is closed.
Normal state where INFO 4 is transmitted to the S interface. The line interface
remains in this state as long as neither a deactivation nor a test mode is requested,
and the receiver does not loose synchronism. When receiver synchronism is lost,
INFO 2 is sent automatically. After reception of INFO 3, the transmitter continues
sending INFO 4.
This state is reached when the line interface has lost synchronism in the state G3
activated.
This state is triggered by a deactivation request DR. It is an unstable state: status DI
(state “G4 wait for DR”) is issued by the DELIC when either INFO 0 is received, or an
internal timer of 32 ms expires.
Final state after a deactivation request. The line interface remains in this state until a
response to DI (in other words DC) is issued.
Single alternating pulses are sent on the S interface (2 kHz repetition rate).
Continuous alternating pulses are sent on the S interface (96 kHz).
3-17
Interface Description
DELIC
2003-08