Register 0B2H: TW8E Timeslot Configuration #1
This register configures the path termination mode of timeslots 1 to 8 of the TW8E.
TMODE1[1:0]-TMODE8[1:0]:
Bit
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
The timeslot path termination mode select register bits (TMODE1[1:0]-TMODE8[1:0])
configures the mode settings for timeslots 1 to 8 of the TW8E. Timeslots are numbered in
order of transmission on the working transmit serial data stream. Timeslot #1 is the first byte
transmitted and timeslot #12 is the last byte transmitted. The setting stored in TMODEx[1:0]
(x can be 1-8) determines which set of TelecomBus control signals are to be encoded in
8B/10B characters.
TMODEx[1]
0
0
1
1
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
TMODEx[0]
0
1
0
1
TMODE5[1]
TMODE5[0]
TMODE4[1]
TMODE4[0]
TMODE3[1]
TMODE3[0]
TMODE2[1]
TMODE2[0]
TMODE1[1]
TMODE1[0]
Function
TMODE8[1]
TMODE8[0]
TMODE7[1]
TMODE7[0]
TMODE6[1]
TMODE6[0]
Functional Description
Reserved
HPT level. This mode must be used when in TelecomBus
mode where valid V1/V2 pointers must be preserved.
LPT level. This mode must be used for SBI336 mode and in
TelecomBus mode with a valid V5 signal but without valid
V1/V2 pointers.
Reserved
SBSLITE™ Telecom Standard Product Data Sheet
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Preliminary
208