10.19 Microprocessor Interface
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-2010883, Issue 2
As each message arrives, the CRC-16 and valid bit is checked; if the valid bit is not set the
message is discarded, if it fails the CRC check it is flagged as being in error and an interrupt is
generated if enabled. If the CRC-16 is OK, regardless of the valid bit, the Page Link, User and
Aux bits are passed on immediately. If the FIFO erroneously overflows, an interrupt is generated.
The Microprocessor Interface block provides normal and test mode registers, and logic required
to connect to the microprocessor interface. The normal mode registers are required for normal
operation, and test mode registers are used to enhance testability of the SBSLITE.
Address
000H
001H
002H
003H
004H
005H
006H
007H
008H
009H – 00FH
010H
011H
012H
013H
014H
015H
016H
017H
020H
021H
022H
023H
024H – 027H
028H
029H
02AH
02BH
02CH – 02FH
030H
031H
032H
Register
SBSLITE Master Reset
SBSLITE Master Configuration
SBSLITE Revision/Part Number
SBSLITE Part Number/Manufacturer ID
SBSLITE Master Bypass
SBSLITE Master SPE Control #1
SBSLITE Master SPE Control #2
SBSLITE Receive Synchronization Delay
SBSLITE In-Band Link User Bits
SBSLITE Reserved
SBSLITE Master Interrupt Source
SBSLITE Interrupt Register
SBSLITE Interrupt Enable Register
SBSLITE Loopback Configuration
SBSLITE Master Clock Monitor #1, Accumulation Trigger
SBSLITE Master Clock Monitor #2
SBSLITE Master Interrupt Enable Register
SBSLITE Free User Register
ISTA Incoming Parity Configuration
ISTA Incoming Parity Status
ISTA TelecomBus Configuration
ISTA Reserved
Reserved
IMSU Configuration
IMSU Interrupt Status and Memory Page Update
IMSU Indirect Time Switch Address
IMSU Indirect Time Switch Data
Reserved
ICASM CAS Enable Indirect Address
ICASM CAS Enable Indirect Control
ICASM CAS Enable Indirect Data
SBSLITE™ Telecom Standard Product Data Sheet
Preliminary
66

Related parts for PM8611-BIAP