S912XET512J3VALR Freescale Semiconductor, S912XET512J3VALR Datasheet - Page 993

no-image

S912XET512J3VALR

Manufacturer Part Number
S912XET512J3VALR
Description
16-bit Microcontrollers - MCU 16 BIT,512K FLASH
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S912XET512J3VALR

Rohs
yes
Core
HCS12X
Processor Series
MC9S12XE
Data Bus Width
16 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
512 KB
Data Ram Size
32 KB
On-chip Adc
Yes
Operating Supply Voltage
3.13 V to 5.5 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
LQFP-112
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S912XET512J3VALR
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
26.4.2.5
The Load Data Field command is executed to provide FCCOB parameters for multiple P-Flash blocks for
a future simultaneous program operation in the P-Flash memory space.
Upon clearing CCIF to launch the Load Data Field command, the FCCOB registers will be transferred to
the Memory Controller and be programmed in the block specified at the global address given with a future
Program P-Flash command launched on a P-Flash block. The CCIF flag will set after the Load Data Field
operation has completed. Note that once a Load Data Field command sequence has been initiated, the Load
Data Field command sequence will be cancelled if any command other than Load Data Field or the future
Program P-Flash is launched. Similarly, if an error occurs after launching a Load Data Field or Program
P-Flash command, the associated Load Data Field command sequence will be cancelled.
Freescale Semiconductor
FERSTAT
Register
FSTAT
Load Data Field Command
1. Global address [2:0] must be 000
CCOBIX[2:0]
MGSTAT1
MGSTAT0
EPVIOLIF
Table 26-41. Load Data Field Command FCCOB Requirements
ACCERR
Error Bit
FPVIOL
000
001
010
011
100
101
Table 26-40. Read Once Command Error Handling
MC9S12XE-Family Reference Manual Rev. 1.25
Global address [15:0] of phrase location to be programmed
Set if CCOBIX[2:0] != 001 at command launch
Set if a Load Data Field command sequence is currently active
Set if command not available in current mode (see
Set if an invalid phrase index is supplied
None
Set if any errors have been encountered during the read
Set if any non-correctable errors have been encountered during the read
None
0x05
FCCOB Parameters
Word 0
Word 1
Word 2
Word 3
Error Condition
Chapter 26 384 KByte Flash Module (S12XFTM384K2V1)
Global address [22:16] to
identify P-Flash block
Table
26-30)