FX1S-30MR-ES/UL MITSUBISHI, FX1S-30MR-ES/UL Datasheet - Page 178

PLC, 16 IN, 14 RELAY OUT, 110V/2

FX1S-30MR-ES/UL

Manufacturer Part Number
FX1S-30MR-ES/UL
Description
PLC, 16 IN, 14 RELAY OUT, 110V/2
Manufacturer
MITSUBISHI
Datasheet

Specifications of FX1S-30MR-ES/UL

No. Of Analogue Inputs
16
No. Of Analogue Outputs
14
Ip/nema Rating
IP10
Approval Bodies
CE, CUL, UL
External Depth
49mm
External Length / Height
90mm
External Width
60mm
Mounting Type
Panel
5.6.5
FX Series Programmable Controlers
specified high speed counter reaches the value in the HSCS instruction.
Points to note:
a) It is recommended that the drive input used for the high speed counter functions; HSCS,
b) If more than one high speed counter function is used for a single counter the selected flag
c) All high speed counter functions use an interrupt process, hence, all destination devices (D)
Note:
For all units Max. 6 simultaneously active HSCS/R and HSZ instructions. Please remember
that the use of high speed counter functions has a direct impact on the maximum allowable
counting speed! See page 4-22 for further details.
Use of interrupt pointers
FX
devices (D). This enables interrupt routines to be triggered directly when the value of the
HSCR (FNC 54)
specified as the destination (D) is reset. In the example above, Y10 would be reset only when
C255’s value stepped from 199 to 200 or from 201 to 200. If the current value of C255 was
forced to equal 200 by test techniques, output Y10 would NOT reset.
For further, general points, about using high speed counter functions, please see the
subsection ‘Points to note’ under the HSCS (FNC 53). Relevant points are; a, b, and c.
Please also reference the note about the number of high speed instructions allowable.
HSCR
FNC 54
(High speed
counter
reset)
Mnemonic
HSCR, HSCZ is the special auxiliary RUN contact M8000.
devices (D) should be kept within 1 group of 8 devices, i.e. Y0-7, M10-17.
are updated immediately.
2N
and FX
2NC
Resets the
selected output
when the
specified high
speed counter
equals the test
value
MPUs can use interrupt pointers I010 through I060 (6 points) as destination
Function
K, H,
KnX, KnY,
KnM, KnS,
T, C, D, V, Z
S
1
Operation :
The HSCR, compares the current value of the
selected high speed counter (S
selected value (S
value changes to a value equal to S
C
Note:
C = C235 to
C255, or
available high
speed
counters
Operands
S
2
Y, M, S
C
Note:
If C, use same
counter as S
1
). When the counters current
D
2
Applied Instructions 5
DHSCR:
13 steps
Program steps
5-56
2
1
) against a
, the device