FX1S-30MR-ES/UL MITSUBISHI, FX1S-30MR-ES/UL Datasheet - Page 180

PLC, 16 IN, 14 RELAY OUT, 110V/2

FX1S-30MR-ES/UL

Manufacturer Part Number
FX1S-30MR-ES/UL
Description
PLC, 16 IN, 14 RELAY OUT, 110V/2
Manufacturer
MITSUBISHI
Datasheet

Specifications of FX1S-30MR-ES/UL

No. Of Analogue Inputs
16
No. Of Analogue Outputs
14
Ip/nema Rating
IP10
Approval Bodies
CE, CUL, UL
External Depth
49mm
External Length / Height
90mm
External Width
60mm
Mounting Type
Panel
FX Series Programmable Controlers
The following points should be read while studying the example on the right of the page.
Please note, all normal rules associated with high speed counters still apply.
The data table is p rocessed on e ‘record
number’ at a time, i.e only 1 record is ever
active as the comparison data. The currently
active record number is stored in data register
D8130. As the comparison value for the active
record is ‘reached’, the assigned ‘Y’ device is
SET or RESET and the active ‘Record number’
is incremented by 1. Once all records in a data
table have been processed, the current record
pointer (D8130) is reset to 0 (the table is then
ready to process again) and the operation
complete flag M8131 is set ON.
If the high speed counter is reset (by program
or hardware input), when it resumes counting
and reaches the first record’s comparison value,
the M8131 flag will be reset. Both the status of
M8131 and contents of D8130 are not editable
by the user. If the DHSZ instruction is turned
OFF then all associated flags are reset.
Care should be exercised when resetting the
high speed counter or turning OFF the DHSZ
instruct as all associated ‘Y’ output devices will
remain in their last state, i.e. if an output was
ON it will remain ON until independently reset
by the user.
Th e d ata w ith in ina ct ive re co rd s ca n b e
changed during operation allowing data tables
to be updated. Any change made is processed
at the end of the current program scan. The
HSZ instruction will continue to process only the
active data record, i.e. it will not reset due to the
updating of an inactive data record.
When the DHSZ instruction is initially activated it will not process a comparison until the
following program scan as the CPU requires a slight time delay to initialize the comparison
table.
number
Record
[D8130]
0
1
2
3
4
M8000
X17
(lower/upper
Comparison
[D150, D151]
[D154, D155]
[D158, D159]
[D162, D163]
[D166, D167]
register)
DHSZ D150
M8131
D8130
[D, D
value
K321
K432
K543
K765
K765
Y10
Y37
765
654
543
432
321
+1
]
0 1 2 3 4 0
C251 reset
Selected ’Y’
H10 (Y10)
H10 (Y10)
H10 (Y10)
H10 (Y10)
H37 (Y37)
Applied Instructions 5
Output
Device
[D152]
[D156]
[D160]
[D164]
[D168]
[D
K5
+2
]
5-58
C251
ON
OFF
SET/RESET
0=RESET)
’Y’Device
K9999
(1=SET,
M8130
C251
[D153]
[D157]
[D161]
[D165]
[D169]
[D
K1
K0
K1
K0
K1
+3
]

Related parts for FX1S-30MR-ES/UL