Specifications of FX1S-30MR-ES/UL

No. Of Analogue Inputs
16
No. Of Analogue Outputs
14
Ip/nema Rating
IP10
Approval Bodies
CE, CUL, UL
External Depth
49mm
External Length / Height
90mm
External Width
60mm
Mounting Type
Panel
6.12
FX Series Programmable Controller
Miscellaneous Devices (M8160 to M8199)
For symbol key see page 6-1.
M8160
M8161
M8162
M8163 -M8166 Reserved
M8167
M8168
M8169
M8170 ( R)
X0 pulse catch
M8171 ( R)
X1 pulse catch
M8172 ( R)
X2 pulse catch
M8173 ( R)
X3 pulse catch
M8174 ( R)
X4 pulse catch
M8175 ( R)
X5 pulse catch
M8176 -M8179 Reserved
Diagnostic
Device
Reserved
Selection of XCH operation
to swap bytes in a single
data word
Selection of 8 bit operations
for applied instructions
ASC, RS, ASCI, HEX, CCD
High speed mode for the
PRUN instruction, 2 data
words Read/write only
Selection of hexadecimal
input mode for the HKY
instruction
Selection of BCD mode for
use with the SMOV instruc-
tion
When the leading edge of a
pulse is received at an input
from the range X0 to X5 the
associated M device detailed
here is set ON. By resetting
the same device within the
user program the next pulse
occurrence will again set the
M coil ON. Hence, fast input
pulses are ‘caught’ and
stored. This operation
requires the EI (FNC04)
instruction to be active. For
details see page 6-7
Operation
M8180
M8181
(I010)
M8182
(I020)
M8183
(I030)
M8184
(I040)
M8185
(I050)
M8186
(I060)
M8187 -M8189 Reserved
M8190
(+ MOV = SQR)
M8191
(+ MOV = FLT)
M8192
(+SMOV=SORT)
M8193
(+ RAMP = SER)
M8194
(+ RAMP = RS)
M8195
(+ FMOV = CCD)
M8196
(+FMOV = ASCI)
M8197
(+FMOV = HEX)
M8198
M8199
Diagnostic
Device
Reserved
These special M coils can be
entered into the HSCS (FNC
53) and HSCR (FNC
54)instructions instead of the
associated Interrupt Pointers
when using old version of pro-
gramming software or hand
held programmers.
More details on this can be
found in the ‘Introduction’ to
this manual.
These special M coils modify
the instruction noted in the
brackets as ‘+
form the same task as the
instruction mnemonic identi-
fied as ‘=
allow old versions of program-
ming software or hand held
programmers to access the
higher functions introduced on
the FX CPU ver 3.07 and the
FX
this can be found in the ‘Intro-
duction’ to this manual.
When this device is set ON it
reverses the operation of the
Source and Destination devices
specified in the instruction.
More details on this can be
found in the ‘Introduction’ to this
manual.
Reserved
2C
units. More details on
Operation
Diagnostic Devices 6
6-12
’. This is to
’ to per-

Related parts for FX1S-30MR-ES/UL