mt90502ag2 Zarlink Semiconductor, mt90502ag2 Datasheet - Page 148

no-image

mt90502ag2

Manufacturer Part Number
mt90502ag2
Description
Multi-channel Aal2 Sar
Manufacturer
Zarlink Semiconductor
Datasheet
Address: 60Ah
Label: status2
Reset Value: 0000h
reserved
rxa_parity_error
rxb_parity_error
rxc_parity_error
reserved
Address: 60Ch
Label: status2_ie
Reset Value: 0000h
reserved
rxa_parity_error_ie
rxb_parity_error_ie
rxc_parity_error_ie
reserved
Address: 60Eh
Label: control2
Reset Value: 0000h
rxa_null_elim
rxb_null_elim
rxc_null_elim
phy_alarm_mode
reserved
Label
Label
Label
Position Type
Position
15:8
1:0
3:2
5:4
7:6
Bit
15:6
Bit
2:0
3
4
5
Bit Position Type
RW Port A Null Cell Elimination. “00”=no Null-Cell Deletion; “01” = reserved; “10” =
RW Port B Null Cell Elimination. “00”=no Null-Cell Deletion; “01” = reserved; “10” =
RW Port C Null Cell Elimination. “00”=no Null-Cell Deletion; “01” = reserved; “10” =
RW “00” = Never detect PHY Alarm; “01” = active-high signal; “10” = active-low
RW Reserved. Must always be “0000_0000”
15:6
Type
2:0
Table 106 - UTOPIA Interrupt Enable Register 2
RO Reserved. Always read as “000”
RO Reserved. Always read as “0000_0000_00”
3
4
5
IE When ‘1’ and the corresponding status bit is ‘1’ an interrupt will be generated.
IE When ‘1’ and the corresponding status bit is ‘1’ an interrupt will be generated.
IE When ‘1’ and the corresponding status bit is ‘1’ an interrupt will be generated.
Delete Null-Cells (UNI); “11” = Delete Null-Cells (NNI).
Delete Null-Cells (UNI); “11” = Delete Null-Cells (NNI).
Delete Null-Cells (UNI); “11” = Delete Null-Cells (NNI).
signal; “11” = reserved.
Table 107 - UTOPIA Control Register 2
Table 105 - UTOPIA Status Register 2
ROL Reserved. Always read as “000”
ROL Parity error on UTOPIA port A
ROL Parity error on UTOPIA port B
ROL Parity error on UTOPIA port C
ROL Reserved. Always read as “0000_0000_00”
Zarlink Semiconductor Inc.
MT90502
148
Description
Description
Description
Data Sheet

Related parts for mt90502ag2