ATUC128L4U Atmel Corporation, ATUC128L4U Datasheet - Page 327

no-image

ATUC128L4U

Manufacturer Part Number
ATUC128L4U
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATUC128L4U

Flash (kbytes)
128 Kbytes
Pin Count
48
Max. Operating Frequency
50 MHz
Cpu
32-bit AVR
# Of Touch Channels
17
Hardware Qtouch Acquisition
Yes
Max I/o Pins
36
Ext Interrupts
36
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
1
Twi (i2c)
2
Uart
4
Lin
4
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
460
Analog Comparators
8
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
16
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.62 to 3.6
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
18
Input Capture Channels
12
Pwm Channels
35
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATUC128L4U-AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATUC128L4U-AUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATUC128L4U-U
Manufacturer:
ATMEL
Quantity:
3 006
15.5.3.2
15.5.4
32142A–12/2011
Peripheral events
Alarm interrupt
prescaler when the AST is enabled. The bit is selected by the Interval Select field in the corre-
sponding Periodic Interval Register (PIRn.INSEL), resulting in a periodic interrupt frequency of
where f
The corresponding PERn bit in the Status Register (SR) will be set when the selected bit in the
prescaler has a 0-to-1 transition.
Because of synchronization, the transfer of the INSEL value will not happen immediately. When
changing/setting the INSEL value, the user must make sure that the prescaler bit number INSEL
will not have a 0-to-1 transition before the INSEL value is transferred to the register. In that case,
the first periodic interrupt after the change will not be triggered.
The AST can also generate alarm interrupts. If the ALARMn bit in IMR is one, the AST will gen-
erate an interrupt request when the counter value matches the selected alarm value, when the
AST is enabled. The alarm value is selected by writing the value to the VALUE field in the corre-
sponding Alarm Register (ARn.VALUE).
The corresponding ALARMn bit in SR will be set when the counter reaches the selected alarm
value.
Because of synchronization, the transfer of the alarm value will not happen immediately. When
changing/setting the alarm value, the user must make sure that the counter will not count the
selected alarm value before the value is transferred to the register. In that case, the first alarm
interrupt after the change will not be triggered.
If the Clear on Alarm bit in the Control Register (CR.CAn) is one, the corresponding alarm inter-
rupt will clear the counter and set the OVF bit in the Status Register. This will generate an
overflow interrupt if the OVF bit in IMR is set.
The AST can generate a number of peripheral events:
The PERn peripheral event(s) is generated the same way as the PER interrupt, as described in
Section
interrupt, as described in
way as the OVF interrupt, as described in
• OVF
• PER0
• PER1
• ALARM0
• ALARM1
CS
15.5.3.1. The ALARMn peripheral event(s) is generated the same way as the ALARM
is the frequency of the selected clock source.
Section
15.5.3.2. The OVF peripheral event is generated the same
f
PA
Section
=
------------------------ -
2
INSEL
f
CS
15.5.3-
+
ATUC64/128/256L3/4U
1
327