ATUC128L4U Atmel Corporation, ATUC128L4U Datasheet - Page 888

no-image

ATUC128L4U

Manufacturer Part Number
ATUC128L4U
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATUC128L4U

Flash (kbytes)
128 Kbytes
Pin Count
48
Max. Operating Frequency
50 MHz
Cpu
32-bit AVR
# Of Touch Channels
17
Hardware Qtouch Acquisition
Yes
Max I/o Pins
36
Ext Interrupts
36
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
1
Twi (i2c)
2
Uart
4
Lin
4
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
460
Analog Comparators
8
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
16
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.62 to 3.6
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
18
Input Capture Channels
12
Pwm Channels
35
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATUC128L4U-AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATUC128L4U-AUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATUC128L4U-U
Manufacturer:
ATMEL
Quantity:
3 006
34.6.7.10
32142A–12/2011
MEMORY_READ
The 4 MSB of the 36 bit SAB address are submitted together with the size field (2 bits). Then fol-
lows the 4 remaining address bytes and finally the data bytes. The size of the transfer is
specified using the values from the following table:
Table 34-40. Size Field Decoding
Below is an example write command:
The length field is set to 0x0009 because there are 9 bytes of additional data: 5 address and size
bytes and 4 bytes of data. The address and size field indicates that words should be written to
address 0x500000004. The data written to 0x500000004 is 0xCAFEBABE.
Table 34-41. MEMORY_WRITE Details
This command enables reading of memory/registers on the Service Access Bus (SAB). The
MEMORY_READ command allows words, halfwords, and bytes to be read from a continuous
sequence of addresses in one operation. The user must supply:
Size field
00
01
10
11
Command
Command value
Additional data
Possible responses
1. 0x55 (sync)
2. 0x80 (command)
3. 0x00 (length MSB)
4. 0x09 (length LSB)
5. 0x25 (size and address MSB, the two MSB of this byte are unused and set to zero)
6. 0x00
7. 0x00
8. 0x00
9. 0x04 (address LSB)
10. 0xCA
11. 0xFE
12. 0xBA
13. 0xBE
14. 0xXX (CRC MSB)
15. 0xXX (CRC LSB)
Description
Byte transfer
Halfword transfer
Word transfer
Reserved
Details
0x80
Size, Address and Data
0xC2: MEMORY_READWRITE_STATUS
0x41: NACK
(Section
ATUC64/128/256L3/4U
34.6.8.2)
(Section
34.6.8.5)
888