ATUC128L4U Atmel Corporation, ATUC128L4U Datasheet - Page 945

no-image

ATUC128L4U

Manufacturer Part Number
ATUC128L4U
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATUC128L4U

Flash (kbytes)
128 Kbytes
Pin Count
48
Max. Operating Frequency
50 MHz
Cpu
32-bit AVR
# Of Touch Channels
17
Hardware Qtouch Acquisition
Yes
Max I/o Pins
36
Ext Interrupts
36
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
1
Twi (i2c)
2
Uart
4
Lin
4
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
460
Analog Comparators
8
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
16
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.62 to 3.6
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
18
Input Capture Channels
12
Pwm Channels
35
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATUC128L4U-AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATUC128L4U-AUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATUC128L4U-U
Manufacturer:
ATMEL
Quantity:
3 006
38.3.5
38.3.6
38.3.7
32142A–12/2011
WDT
GPIO
SPI
1. Clearing the Watchdog Timer (WDT) counter in second half of timeout period will
2. WDT Control Register does not have synchronization feedback
1. Clearing Interrupt flags can mask other interrupts
1. SPI data transfer hangs with CSR0.CSAAT==1 and MR.MODFDIS==0
2. Disabling SPI has no effect on the SR.TDRE bit
None.
issue a Watchdog reset
If the WDT counter is cleared in the second half of the timeout period, the WDT will immedi-
ately issue a Watchdog reset.
Fix/Workaround
Use twice as long timeout period as needed and clear the WDT counter within the first half
of the timeout period. If the WDT counter is cleared after the first half of the timeout period,
you will get a Watchdog reset immediately. If the WDT counter is not cleared at all, the time
before the reset will be twice as long as needed.
When writing to the Timeout Prescale Select (PSEL), Time Ban Prescale Select (TBAN),
Enable (EN), or WDT Mode (MODE) fieldss of the WDT Control Register (CTRL), a synchro-
nizer is started to propagate the values to the WDT clcok domain. This synchronization
takes a finite amount of time, but only the status of the synchronization of the EN bit is
reflected back to the user. Writing to the synchronized fields during synchronization can lead
to undefined behavior.
Fix/Workaround
-When writing to the affected fields, the user must ensure a wait corresponding to 2 clock
cycles of both the WDT peripheral bus clock and the selected WDT clock source.
-When doing writes that changes the EN bit, the EN bit can be read back until it reflects the
written value.
When clearing interrupt flags in a GPIO port, interrupts on other pins of that port, happening
in the same clock cycle will not be registered.
Fix/Workaround
Read the PVR register of the port before and after clearing the interrupt to see if any pin
change has happened while clearing the interrupt. If any change occurred in the PVR
between the reads, they must be treated as an interrupt.
When CSR0.CSAAT==1 and mode fault detection is enabled (MR.MODFDIS==0), the SPI
module will not start a data transfer.
Fix/Workaround
Disable mode fault detection by writing a one to MR.MODFDIS.
Disabling SPI has no effect on the SR.TDRE bit whereas the write data command is filtered
when SPI is disabled. Writing to TDR when SPI is disabled will not clear SR.TDRE. If SPI is
disabled during a PDCA transfer, the PDCA will continue to write data to TDR until its buffer
is empty, and this data will be lost.
Fix/Workaround
Disable the PDCA, add two NOPs, and disable the SPI. To continue the transfer, enable the
SPI and PDCA.