st7pmc2s6 STMicroelectronics, st7pmc2s6 Datasheet - Page 35

no-image

st7pmc2s6

Manufacturer Part Number
st7pmc2s6
Description
8-bit Mcu For Automotive With Nested Interrupts, Flash, 10-bit Adc, Brushless Motor Control, 5 Timers, Spi, Linsci?
Manufacturer
STMicroelectronics
Datasheet
ST7MC1K2-Auto, ST7MC1K6-Auto, ST7MC2S4-Auto, ST7MC2S6-Auto
Figure 6.
1. If the ICCCLK or ICCDATA pins are only used as outputs in the application, no signal isolation is necessary. As soon as the
2. During the ICC session, the programming tool must control the RESET pin. This can lead to conflicts between the
3. The use of Pin 7 of the ICC connector depends on the programming tool architecture. This pin must be connected when
4. Pin 9 has to be connected to the OSC1 (or OSCIN) pin of the ST7 when the clock is not available in the application or if the
4.5
To perform ICP the microcontroller must be switched to ICC (in-circuit communication) mode by an
external controller or programming tool.
Depending on the ICP code downloaded in RAM, Flash memory programming can be fully customized
(number of bytes to program, program locations, or selection serial communication interface for
downloading).
When using an STMicroelectronics or third-party programming tool that supports ICP and the specific
microcontroller device, the user needs only to implement the ICP hardware interface on the application
board (see
Application
power supply
programming tool is plugged to the board, even if an ICC session is not in progress, the ICCCLK and ICCDATA pins are
not available for the application. If they are used as inputs by the application, isolation such as a serial resistor has to
implemented in case another device forces the signal. Refer to the programming tool documentation for recommended
resistor values.
programming tool and the application reset circuit if it drives more than 5mA at high level (push-pull output or pull-up
resistor < 1K). A schottky diode can be used to isolate the application reset circuit in this case. When using a classical RC
network with R > 1K or a reset management IC with open drain output and pull-up resistor > 1K, no additional components
are needed. In all cases the user must ensure that no external reset is generated by the application during the ICC session.
using most ST programming tools (it is used to monitor the application power supply). Please refer to the programming tool
manual.
selected clock option is not programmed in the option byte. ST7 devices with multi-oscillator capability need to have OSC2
grounded in this case.
Figure
Typical ICC interface
ICP (in-circuit programming)
6). For more details on the pin locations, refer to the device pinout description.
(See note 3)
C
L2
Programming tool
(see note 4)
Optional
C
ST7
L1
10k
10
9
ICC connector
7
8
5
6
ICC cable
4
3
1
2
HE10 connector type
ICC connector
Flash program memory
reset source
See note 2
Application I/O
Application
See note 1
Application board
35/371

Related parts for st7pmc2s6