HD6412373R RENESAS [Renesas Technology Corp], HD6412373R Datasheet - Page 166

no-image

HD6412373R

Manufacturer Part Number
HD6412373R
Description
Renesas 16-Bit Single-Chip Microcomputer H8S Family/H8S/2300 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet
Section 4 Exception Handling
4.4
Traces are enabled in interrupt control mode 2. Trace mode is not activated in interrupt control
mode 0, irrespective of the state of the T bit. For details on interrupt control modes, see section 5,
Interrupt Controller.
If the T bit in EXR is set to 1, trace mode is activated. In trace mode, a trace exception occurs on
completion of each instruction. Trace mode is not affected by interrupt masking. Table 4.3 shows
the state of CCR and EXR after execution of trace exception handling. Trace mode is canceled by
clearing the T bit in EXR to 0. The T bit saved on the stack retains its value of 1, and when control
is returned from the trace exception handling routine by the RTE instruction, trace mode resumes.
Trace exception handling is not carried out after execution of the RTE instruction.
Interrupts are accepted even within the trace exception handling routine.
Table 4.3
Legend:
1:
0:
—: Retains value prior to execution.
4.5
Interrupts are controlled by the interrupt controller. The interrupt controller has two interrupt
control modes and can assign interrupts other than NMI to eight priority/mask levels to enable
multiplexed interrupt control. The source to start interrupt exception handling and the vector
address differ depending on the product. For details, refer to section 5, Interrupt Controller.
The interrupt exception handling is as follows:
1. The values in the program counter (PC), condition code register (CCR), and extended register
2. The interrupt mask bit is updated and the T bit is cleared to 0.
3. A vector address corresponding to the interrupt source is generated, the start address is loaded
Rev.7.00 Mar. 18, 2009 page 98 of 1136
REJ09B0109-0700
(EXR) are saved in the stack.
from the vector table to the PC, and program execution starts from that address.
Interrupt Control Mode
Set to 1
Cleared to 0
Trace Exception Handling
Interrupt Exception Handling
Status of CCR and EXR after Trace Exception Handling
0
2
1
I
Trace exception handling cannot be used.
CCR
UI
I2 to I0
EXR
T
0