PEF2256 INFINEON [Infineon Technologies AG], PEF2256 Datasheet - Page 136

no-image

PEF2256

Manufacturer Part Number
PEF2256
Description
E1/T1/J1 Framer and Line Interface Component for Long- and Short-Haul Applications
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEF2256EV2.1ES
Manufacturer:
HARRIS
Quantity:
101
Part Number:
PEF2256EV2.2
Manufacturer:
INFINEON
Quantity:
513
Part Number:
PEF2256EV2.2
Manufacturer:
LANTIQ
Quantity:
8 000
Part Number:
PEF2256H
Manufacturer:
infineon
Quantity:
6
Part Number:
PEF2256H V1.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEF2256HV
Manufacturer:
INF
Quantity:
20 000
Part Number:
PEF2256HV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
PEF2256HV2.1
Quantity:
116
Part Number:
PEF2256HV2.2
Manufacturer:
INFINEON
Quantity:
672
Part Number:
PEF2256HV2.2
Manufacturer:
INFINEON
Quantity:
8 000
Part Number:
PEF2256HV2.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
PEF2256HV2.2
Quantity:
7
Table 32
Buffer Size
(SIC1.RBS1/0)
Bypass
Short buffer
1 frame
2 frames
1)
Figure 51
A slip condition is detected when the write pointer (W) and the read pointer (R) of the
memory are nearly coincident, i.e. the read pointer is within the slip limits (S +, S –). If a
slip condition is detected, a negative slip (one frame or one half of the current buffer size
is skipped) or a positive slip (one frame or one half of the current buffer size is read out
twice) is performed at the system interface, depending on the difference between RCLK
and the current working clock of the receive backplane interface, i.e. on the position of
pointer R and W within the memory. A positive/negative slip is indicated by the interrupt
status bits ISR3.RSP and ISR3.RSN.
User’s Manual
Hardware Description
In bypass mode the clock provided on pin SCLKR is ignored. Clocking is done with RCLK.
1)
gives an idea of operation of the receive elastic buffer:
Receive Buffer Operation Modes (T1/J1)
TS Offset program.
(RC1/0) + SYPR = input
Disabled
Not recommended,
recommended:
SYPR = output
Not recommended,
recommended:
SYPR = output
enabled
136
Functional Description T1/J1
Slip perform.
No
Yes
Yes
Yes
DS1.1, 2003-10-23