PEF2256 INFINEON [Infineon Technologies AG], PEF2256 Datasheet - Page 248

no-image

PEF2256

Manufacturer Part Number
PEF2256
Description
E1/T1/J1 Framer and Line Interface Component for Long- and Short-Haul Applications
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEF2256EV2.1ES
Manufacturer:
HARRIS
Quantity:
101
Part Number:
PEF2256EV2.2
Manufacturer:
INFINEON
Quantity:
513
Part Number:
PEF2256EV2.2
Manufacturer:
LANTIQ
Quantity:
8 000
Part Number:
PEF2256H
Manufacturer:
infineon
Quantity:
6
Part Number:
PEF2256H V1.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEF2256HV
Manufacturer:
INF
Quantity:
20 000
Part Number:
PEF2256HV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
PEF2256HV2.1
Quantity:
116
Part Number:
PEF2256HV2.2
Manufacturer:
INFINEON
Quantity:
672
Part Number:
PEF2256HV2.2
Manufacturer:
INFINEON
Quantity:
8 000
Part Number:
PEF2256HV2.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
PEF2256HV2.2
Quantity:
7
Receive Control 0 (Read/Write)
Value after reset: 00
RC0
SWD
ASY4
CRCI
XCRCI
RDIS
User’s Manual
Hardware Description
SWD
7
Service Word Condition Disable
0 =
1 =
Select Loss of Sync Condition
0 =
1 =
Automatic CRC4 Bit Inversion
If set, all CRC bits of one outgoing submultiframe are inverted in case
a CRC error is flagged for the previous received submultiframe. This
function is logically ored with RC0.XCRCI.
Transmit CRC4 Bit Inversion
If set, the CRC bits in the outgoing data stream are inverted before
transmission. This function is logically ored with RC0.CRCI.
Receive Data Input Sense
Digital interface, dual-rail:
0 =
1 =
Digital Interface, CMI:
0 =
1 =
ASY4
H
Standard operation. Three or four consecutive incorrect service
words (depending on bit RC0.ASY4) causes loss of
synchronization.
Errors in service words have no influence when in synchronous
state. However, they are used for the resynchronization
procedure.
Standard operation. Three consecutive incorrect FAS words or
three consecutive incorrect service words causes loss of
synchronization.
Four consecutive incorrect FAS words or four consecutive
incorrect service words causes loss of synchronization. The
service word condition is disabled by bit RC0.SWD.
Inputs RDIP/RDIN are active low
Inputs RDIP/RDIN are active high
Input ROID is active high
Input ROID is active low
CRCI
XCRCI
248
RDIS
RCO10
RCO9
DS1.1, 2003-10-23
PEF 2256 H/E
RCO8
E1 Registers
0
FALC
(24)
®
56