HD6432646 Hitachi, HD6432646 Datasheet - Page 129

no-image

HD6432646

Manufacturer Part Number
HD6432646
Description
(HD64F264x Series) 16-Bit Microcomputer
Manufacturer
Hitachi
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B37FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B67FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B82FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646B99FCJ
Manufacturer:
MOT
Quantity:
44
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 954
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 700
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C64FCJ
Manufacturer:
RENESAS
Quantity:
1 500
Part Number:
HD6432646C90FCJV
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646D08FCJV
Manufacturer:
RENESAS
Quantity:
1 700
4.2.4
After reset release, MSTPCRA to MSTPCRD are initialized to H'3F, H'FF, H'FF, and
B'11******
Consequently, on-chip supporting module registers cannot be read or written to. Register reading
and writing is enabled when module stop mode is exited.
Note:
4.3
Traces are enabled in interrupt control mode 2. Trace mode is not activated in interrupt control
mode 0, irrespective of the state of the T bit. For details of interrupt control modes, see section 5,
Interrupt Controller.
If the T bit in EXR is set to 1, trace mode is activated. In trace mode, a trace exception occurs on
completion of each instruction.
Trace mode is canceled by clearing the T bit in EXR to 0. It is not affected by interrupt masking.
Table 4-3 shows the state of CCR and EXR after execution of trace exception handling.
Interrupts are accepted even within the trace exception handling routine.
The T bit saved on the stack retains its value of 1, and when control is returned from the trace
exception handling routine by the RTE instruction, trace mode resumes.
Trace exception handling is not carried out after execution of the RTE instruction.
Table 4-3
Interrupt Control Mode
0
2
Legend
1:
0:
—: Retains value prior to execution.
*:
Set to 1
Cleared to 0
Trace exception handling cannot be used.
*1 The value of bits 5 to 0 is undefined.
State of On-Chip Supporting Modules after Reset Release
Traces
*1
Status of CCR and EXR after Trace Exception Handling
, respectively, and all modules except the DTC, enter module stop mode.
*
1
I
CCR
UI
*
I2 to I0
*
EXR
T
*
0
95