HD6432646 Hitachi, HD6432646 Datasheet - Page 559

no-image

HD6432646

Manufacturer Part Number
HD6432646
Description
(HD64F264x Series) 16-Bit Microcomputer
Manufacturer
Hitachi
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B37FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B67FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B82FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646B99FCJ
Manufacturer:
MOT
Quantity:
44
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 954
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 700
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C64FCJ
Manufacturer:
RENESAS
Quantity:
1 500
Part Number:
HD6432646C90FCJV
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646D08FCJV
Manufacturer:
RENESAS
Quantity:
1 700
flag is set but the RDRF flag is not. Consequently, the DTC is not activated, but instead, an ERI
interrupt request is sent to the CPU. Therefore, the error flag should be cleared.
Note: For block transfer mode, see section 13.4, SCI Interrupts.
14.3.7
Switching the Mode: When switching between smart card interface mode and software standby
mode, the following switching procedure should be followed in order to maintain the clock duty.
• When changing from smart card interface mode to software standby mode
[1] Set the data register (DR) and data direction register (DDR) corresponding to the SCK pin to
[2] Write 0 to the TE bit and RE bit in the serial control register (SCR) to halt transmit/receive
[3] Write 0 to the CKE0 bit in SCR to halt the clock.
[4] Wait for one serial clock period.
[5] Make the transition to the software standby state.
• When returning to smart card interface mode from software standby mode
[6] Exit the software standby state.
[7] Write 1 to the CKE0 bit in SCR and output the clock. Signal generation is started with the
the value for the fixed output state in software standby mode.
operation. At the same time, set the CKE1 bit to the value for the fixed output state in software
standby mode.
During this interval, clock output is fixed at the specified level, with the duty preserved.
normal duty.
Operation in GSM Mode
[1] [2] [3]
Normal operation
Figure 14-9 Clock Halt and Restart Procedure
[4] [5]
Software
standby
[6] [7]
Normal operation
525

Related parts for HD6432646