AT91SAM7S256D-AU Atmel, AT91SAM7S256D-AU Datasheet - Page 627

no-image

AT91SAM7S256D-AU

Manufacturer Part Number
AT91SAM7S256D-AU
Description
ARM Microcontrollers - MCU 256K Flash SRAM 64K ARM based MCU
Manufacturer
Atmel
Series
SAM7S256r
Datasheet

Specifications of AT91SAM7S256D-AU

Rohs
yes
Core
ARM
Processor Series
AT91SAM
Data Bus Width
16 bit/32 bit
Maximum Clock Frequency
55 MHz
Program Memory Size
256 KB
Data Ram Size
64 KB
On-chip Adc
Yes
Operating Supply Voltage
3 V to 3.6 V
Operating Temperature Range
- 40 C to + 85 C
Package / Case
LQFP-64
Mounting Style
SMD/SMT
Interface Type
2-Wire, I2S, SPI, USART
Length
7 mm

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7S256D-AU
Manufacturer:
ATMEL
Quantity:
101
Part Number:
AT91SAM7S256D-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7S256D-AU-999
Manufacturer:
Atmel
Quantity:
10 000
40.7.5
40.7.5.1
40.7.5.2
40.7.6
40.7.6.1
40.7.6.2
40.7.6.3
Under certain rare circumstances, when CSS = 00 in PMC_MCKR, and PA1 is set as an input and a transition
occurs on PA1, device malfunction might occur.
Do not transition PA1 as an input when CSS = 00 in PMC_MCKR.
Under certain rare circumstances, reprogramming the CSS value in the PMC_MCKR register (i.e switching the
main clock source) might generate malfunction of the device if the following two actions occur simultaneously.
Note:
When changing CSS in the PMC_MCKR to switch from
Ensure that the processor is executing out of SRAM and ensure no transition occurs on PA1, either as an input or
output, starting from writing to the PMC_MCKR register until MCKRDY = 1.
If the Channel Counter Register value is 0 or 1, the Channel Period Register or Channel Duty Cycle Register is
directly modified when writing the Channel Update Register.
Check the Channel Counter Register before writing the update register.
When Channel Period Register equals 0, the period update is not operational.
Do not write 0 in the period register.
In left aligned mode, the first start value of the counter is 0. For the other periods, the counter starts at 1.
1. Switching from:
2. Program code is being executed out of flash, or a transition is occurring on PA1, either as an input or
Power Management Controller (PMC)
Pulse Width Modulation Controller (PWM)
Problem Fix/Workaround
And
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
PMC: Slow Clock Selected in PMC and a Transition Occurs on PA1
PMC: Programming CSS in PMC_MCKR Register
PWM: Update when PWM_CCNTx = 0 or 1
PWM: Update when PWM_CPRDx = 0
PWM: Counter Start Value
– PLL Clock to Slow Clock or
– PLL Clock to Main Clock or
– Main Clock to PLL Clock or
– Main Clock to Slow Clock
output.
– PLL Clock to Slow Clock or
– PLL Clock to Main Clock or
– Main Clock to PLL Clock or
– Main Clock to Slow Clock
This issue does not occur when transitioning from slow clock to main clock or from slow clock to PLL clock.
SAM7S Series [DATASHEET]