AT91SAM7S256D-AU Atmel, AT91SAM7S256D-AU Datasheet - Page 673

no-image

AT91SAM7S256D-AU

Manufacturer Part Number
AT91SAM7S256D-AU
Description
ARM Microcontrollers - MCU 256K Flash SRAM 64K ARM based MCU
Manufacturer
Atmel
Series
SAM7S256r
Datasheet

Specifications of AT91SAM7S256D-AU

Rohs
yes
Core
ARM
Processor Series
AT91SAM
Data Bus Width
16 bit/32 bit
Maximum Clock Frequency
55 MHz
Program Memory Size
256 KB
Data Ram Size
64 KB
On-chip Adc
Yes
Operating Supply Voltage
3 V to 3.6 V
Operating Temperature Range
- 40 C to + 85 C
Package / Case
LQFP-64
Mounting Style
SMD/SMT
Interface Type
2-Wire, I2S, SPI, USART
Length
7 mm

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7S256D-AU
Manufacturer:
ATMEL
Quantity:
101
Part Number:
AT91SAM7S256D-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7S256D-AU-999
Manufacturer:
Atmel
Quantity:
10 000
40.13.9.4
40.13.9.5
40.13.10 Voltage Regulator
40.13.10.1
40.13.10.2
None.
In receiver mode, when there are two consecutive characters (without timeguard in between), RXBRK is not taken
into account. As a result, the RXBRK flag is not enabled correctly and the frame error flag is set.
Constraints on the transmitter device connected to the SAM7S USART receiver side:
The transmitter may use the timeguard feature or send two STOP conditions. Only one STOP condition is taken
into account by the receiver state machine. After this STOP condition, as there is no valid data, the receiver state
machine will go in idle mode and enable the RXBRK flag.
The DCD signal is active at High level in the USART Modem Mode.
DCD should be active at Low level.
Add an inverter.
Current consumption in Deep Mode is maximum 60 µA instead of 25 µA.
Due to current rejection from VDDIN to VDDCORE, the current consumption in Deep Mode cannot be guaranteed.
Instead, 60 µA is guaranteed whatever the condition.
None.
Maximum load is 50 mA at 85 °C (instead of 100 mA).
Maximum load is 100 mA at 70°C.
None.
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
USART: RXBRK Flag Error in Asynchronous Mode
USART: DCD is active High instead of Low
Voltage Regulator: Current Consumption in Deep Mode
Voltage Regulator: Load Versus Temperature
SAM7S Series [DATASHEET]
6175M–ATARM–26-Oct-12
673

Related parts for AT91SAM7S256D-AU