MA180025 Microchip Technology, MA180025 Datasheet - Page 249

MODULE PLUG-IN PIC18F87J90 PIM

MA180025

Manufacturer Part Number
MA180025
Description
MODULE PLUG-IN PIC18F87J90 PIM
Manufacturer
Microchip Technology
Series
PIC®r
Datasheets

Specifications of MA180025

Accessory Type
Plug-In Module (PIM) - PIC18F87J90
Product
Microcontroller Modules
Silicon Manufacturer
Microchip
Core Architecture
PIC
Core Sub-architecture
PIC18
Silicon Core Number
PIC18F
Silicon Family Name
PIC18FxxJxx
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
PICDEM LCD 2 Demonstration Board (DM163030)
For Use With
DM163030 - KIT DEV PICDEM LCD2
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MA180025
Manufacturer:
Microchip Technology
Quantity:
135
Part Number:
MA180025
Manufacturer:
MICROCHIP
Quantity:
12 000
18.4.14
While in Sleep mode, the I
addresses or data, and when an address match or
complete byte transfer occurs, wake the processor
from Sleep (if the MSSP interrupt is enabled).
18.4.15
A Reset disables the MSSP module and terminates the
current transfer.
18.4.16
In Multi-Master mode, the interrupt generation on the
detection of the Start and Stop conditions allows the
determination of when the bus is free. The Stop (P) and
Start (S) bits are cleared from a Reset or when the
MSSP module is disabled. Control of the I
be taken when the P bit (SSPSTAT<4>) is set, or the
bus is Idle, with both the S and P bits clear. When the
bus is busy, enabling the MSSP interrupt will generate
the interrupt when the Stop condition occurs.
In multi-master operation, the SDA line must be
monitored for arbitration to see if the signal level is the
expected output level. This check is performed in
hardware with the result placed in the BCLIF bit.
The states where arbitration can be lost are:
• Address Transfer
• Data Transfer
• A Start Condition
• A Repeated Start Condition
• An Acknowledge Condition
FIGURE 18-27:
 2010 Microchip Technology Inc.
SDA
SCL
BCLIF
SLEEP OPERATION
EFFECTS OF A RESET
MULTI-MASTER MODE
BUS COLLISION TIMING FOR TRANSMIT AND ACKNOWLEDGE
2
C module can receive
Data changes
while SCL = 0
2
C bus may
SDA released
by master
SDA line pulled low
by another source
PIC18F87J90 FAMILY
18.4.17
Multi-Master mode support is achieved by bus arbitra-
tion. When the master outputs address/data bits onto
the SDA pin, arbitration takes place when the master
outputs a ‘1’ on SDA by letting SDA float high, and
another master asserts a ‘0’. When the SCL pin floats
high, data should be stable. If the expected data on
SDA is a ‘1’ and the data sampled on the SDA pin = 0,
then a bus collision has taken place. The master will set
the Bus Collision Interrupt Flag, BCLIF, and reset the
I
If a transmit was in progress when the bus collision
occurred, the transmission is halted, the BF flag is
cleared, the SDA and SCL lines are deasserted and the
SSPBUF can be written to. When the user services the
bus collision Interrupt Service Routine, and if the I
is free, the user can resume communication by asserting
a Start condition.
If a Start, Repeated Start, Stop or Acknowledge condition
was in progress when the bus collision occurred, the
condition is aborted, the SDA and SCL lines are
deasserted and the respective control bits in the
SSPCON2 register are cleared. When the user services
the bus collision Interrupt Service Routine, and if the I
bus is free, the user can resume communication by
asserting a Start condition.
The master will continue to monitor the SDA and SCL
pins. If a Stop condition occurs, the SSPIF bit will be set.
A write to the SSPBUF will start the transmission of
data at the first data bit regardless of where the
transmitter left off when the bus collision occurred.
In Multi-Master mode, the interrupt generation on the
detection of Start and Stop conditions allows the deter-
mination of when the bus is free. Control of the I
can be taken when the P bit is set in the SSPSTAT
register or the bus is Idle and the S and P bits are
cleared.
2
C port to its Idle state (Figure 18-27).
MULTI -MASTER COMMUNICATION,
BUS COLLISION AND BUS
ARBITRATION
Sample SDA. While SCL is high,
data doesn’t match what is driven
by the master.
Bus collision has occurred.
Set bus collision
interrupt (BCLIF)
DS39933D-page 249
2
2
C bus
C bus
2
C