HD6473937RXV Renesas Electronics America, HD6473937RXV Datasheet - Page 307

MCU 3/5V 60K 100-TQFP

HD6473937RXV

Manufacturer Part Number
HD6473937RXV
Description
MCU 3/5V 60K 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300L SLPr
Datasheet

Specifications of HD6473937RXV

Core Processor
H8/300L
Core Size
8-Bit
Speed
10MHz
Connectivity
SCI
Peripherals
POR, WDT
Number Of I /o
59
Program Memory Size
60KB (60K x 8)
Program Memory Type
OTP
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6473937RXV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
SCI3 operates as follows when receiving data.
SCI3 monitors the communication line, and when it detects a 0 start bit, performs internal
synchronization and begins reception. Reception is carried out in accordance with the relevant
data transfer format in table 10-14. The received data is first placed in RSR in LSB-to-MSB
order, and then the parity bit and stop bit(s) are received. SCI3 then carries out the following
checks.
If no receive error is found in the above checks, bit RDRF is set to 1, and the receive data is stored
in RDR. If bit RIE is set to 1 in SCR3, an RXI interrupt is requested. If the error checks identify a
receive error, bit OER, PER, or FER is set to 1 depending on the kind of error. Bit RDRF retains
its state prior to receiving the data. If bit RIE is set to 1 in SCR3, an ERI interrupt is requested.
Table 10-15 shows the conditions for detecting a receive error, and receive data processing.
Note: No further receive operations are possible while a receive error flag is set. Bits OER,
Table 10-15 Receive Error Detection Conditions and Receive Data Processing
Receive Error Abbreviation Detection Conditions
Overrun error
Framing error
Parity error
Parity check
SCI3 checks that the number of 1 bits in the receive data conforms to the parity (odd or even)
set in bit PM in the serial mode register (SMR).
Stop bit check
SCI3 checks that the stop bit is 1. If two stop bits are used, only the first is checked.
Status check
SCI3 checks that bit RDRF is set to 0, indicating that the receive data can be transferred from
RSR to RDR.
FER, PER, and RDRF must therefore be cleared to 0 before resuming reception.
OER
FER
PER
When the next date receive
operation is completed while bit
RDRF is still set to 1 in SSR
When the stop bit is 0
When the parity (odd or even) set
in SMR is different from that of the
received data
Receive Data Processing
Receive data is not transferred
from RSR to RDR
Receive data is transferred
from RSR to RDR
Receive data is transferred
from RSR to RDR
293