HD6473937RXV Renesas Electronics America, HD6473937RXV Datasheet - Page 364

MCU 3/5V 60K 100-TQFP

HD6473937RXV

Manufacturer Part Number
HD6473937RXV
Description
MCU 3/5V 60K 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300L SLPr
Datasheet

Specifications of HD6473937RXV

Core Processor
H8/300L
Core Size
8-Bit
Speed
10MHz
Connectivity
SCI
Peripherals
POR, WDT
Number Of I /o
59
Program Memory Size
60KB (60K x 8)
Program Memory Type
OTP
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6473937RXV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
MFC
0
0
1
1
MCO: Maximum Carry On. The value of these bits sets the maximum carry on that the FLEX
decoder will follow. For example, if the FLEX decoder receives a carry on of 3 over the air and
MCO is set to 1, the FLEX decoder will only carry on for one frame. (value after reset=3)
12.3.7
The contents of this section apply to the FLEX™ Roaming Decoder. They are not applicable to
the FLEX™ Non-Roaming Decoder.
The timing control packet gives the host control of the timing used when the FLEX decoder is in
asynchronous mode. The packet ID for the timing control packet is 6.
Table 12-9 Timing Control Packet Bit Assignments
Byte 3
Byte 2
Byte 1
Byte 0
AST: A-word Search Time. The value of these bits sets the A-word search time for all
asynchronous A-word searches in units of 80ms (e.g. value of 1 is 80ms, value of 2 is 160ms, etc.)
If the value is 0, the FLEX decoder defaults to the 1-minute (MOT=1) or 4-minute (MOT=0) A-
word search time controlled by the MOT bit in the configuration packet. (Value after reset=0)
ABT: Asynchronous Battery-save Time. The value of these bits sets the battery save time (time
from the beginning of one automatic noise detect to the beginning of the next automatic noise
detect) in asynchronous mode in units of 80ms (e.g. value of 1 is 80ms, value of 2 is 160ms, etc.)
If the value is 0, the battery save time is set to the default value of 1.5 seconds. The minimum
allowed ABT is 320ms, therefore values of 1, 2, 3, and 4 are invalid. (Value after reset=0)
350
1
MFC
0
1
0
1
Bit 7
0
0
AST
ABT
Timing Control Packet
0
7
7
Bit 6
0
0
AST
ABT
6
6
Bit 5
0
0
AST
ABT
5
5
Missing Frame Data Reported
Never
Only during frames 0 through 3
Only during frames 0 through 7
Always
Bit 4
0
0
AST
ABT
4
4
Bit 3
1
0
AST
ABT
3
3
Bit 2
1
0
AST
ABT
2
2
Bit 1
1
0
AST
ABT
1
1
Bit 0
1
0
AST
ABT
0
0

Related parts for HD6473937RXV