HD6473937RXV Renesas Electronics America, HD6473937RXV Datasheet - Page 324

MCU 3/5V 60K 100-TQFP

HD6473937RXV

Manufacturer Part Number
HD6473937RXV
Description
MCU 3/5V 60K 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300L SLPr
Datasheet

Specifications of HD6473937RXV

Core Processor
H8/300L
Core Size
8-Bit
Speed
10MHz
Connectivity
SCI
Peripherals
POR, WDT
Number Of I /o
59
Program Memory Size
60KB (60K x 8)
Program Memory Type
OTP
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6473937RXV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
3. Break detection and processing
When a framing error is detected, a break can be detected by reading the value of the RXD
pin
3X
directly. In a break, the input from the RXD
pin becomes all 0s, with the result that bit FER is
3X
set and bit PER may also be set.
SCI3 continues the receive operation even after receiving a break. Note, therefore, that even
though bit FER is cleared to 0 it will be set to 1 again.
4. Mark state and break detection
When bit TE is cleared to 0, the TXD
pin functions as an I/O port whose input/output direction
3X
and level are determined by PDR and PCR. This fact can be used to set the TXD
pin to the mark
3X
state, or to detect a break during transmission.
To keep the communication line in the mark state (1 state) until bit TE is set to 1, set PCR = 1 and
PDR = 1. Since bit TE is cleared to 0 at this time, the TXD
pin functions as an I/O port and 1 is
3X
output.
To detect a break, clear bit TE to 0 after setting PCR = 1 and PDR = 0.
When bit TE is cleared to 0, the transmission unit is initialized regardless of the current
transmission state, the TXD
pin functions as an I/O port, and 0 is output from the TXD
pin.
3X
3X
5. Receive error flags and transmit operation (synchronous mode only)
When a receive error flag (OER, PER, or FER) is set to 1, transmission cannot be started even if
bit TDRE is cleared to 0. The receive error flags must be cleared to 0 before starting transmission.
Note also that receive error flags cannot be cleared to 0 even if bit RE is cleared to 0.
6. Receive data sampling timing and receive margin in asynchronous mode
In asynchronous mode, SCI3 operates on a basic clock with a frequency 16 times the transfer rate.
When receiving, SCI3 performs internal synchronization by sampling the falling edge of the start
bit with the basic clock. Receive data is latched internally at the 8th rising edge of the basic clock.
This is illustrated in figure 10-23.