HD6473937RXV Renesas Electronics America, HD6473937RXV Datasheet - Page 390

MCU 3/5V 60K 100-TQFP

HD6473937RXV

Manufacturer Part Number
HD6473937RXV
Description
MCU 3/5V 60K 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300L SLPr
Datasheet

Specifications of HD6473937RXV

Core Processor
H8/300L
Core Size
8-Bit
Speed
10MHz
Connectivity
SCI
Peripherals
POR, WDT
Number Of I /o
59
Program Memory Size
60KB (60K x 8)
Program Memory Type
OTP
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6473937RXV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
4. Receiver Shut Down Sequence
The FLEX decoder allows for up to 3 steps associated with shutting down the receiver. When the
FLEX decoder decides to turn off the receiver, the first shut down setting, if enabled, is applied to
the receiver control lines for the corresponding shut down time. At the end of the last used shut
down time, the “Off” setting is applied to the receiver control lines. If the first shut down setting is
not enabled, the FLEX decoder will transition directly from the current on setting to the “Off”
setting. The receiver turn off sequence when all shut down settings are enabled is shown in figure
12-11.
If the receiver is on or being warmed up when the decoder is turned off (by clearing the ON bit in
the Control Packet), the FLEX decoder will execute the receiver shutdown sequence. If the FLEX
decoder is executing the shut down sequence when the FLEX decoder is turned on (by setting the
ON bit in the Control Packet), the FLEX decoder will complete the shut down sequence before
starting the warm up sequence.
LINE SETTING
5. Miscellaneous Receiver States
In addition to the warm up and shut down states, the FLEX decoder has four other receiver states.
When these settings are applied to the receiver control lines, the FLEX decoder will be decoding
the EXTS1 and EXTS0 input signals (or the equivalent internal signals when using the internal
demodulator/data slicer). The timing of these signals and their duration depends on the data the
FLEX decoder decodes. The four settings are as follows:
376
RECEIVER
CONTROL
1600sps Sync Setting:This setting is applied when the FLEX decoder is searching for a 1600
symbols per second signal.
3200sps Sync Setting:This setting is applied when the FLEX decoder is searching for a 3200
symbols per second signal.
1600sps Data Setting:This setting is applied after the FLEX decoder has found the C or C
sync word in a 1600 symbols per second frame.
Sync or Data Setting
1600sps or 3200sps
Figure 12-11 Receiver Shut Down Sequence
Possible
LOBAT
Check
Shut Down
Shut Down
Setting 1
Time 1
Possible
LOBAT
Check
Shut Down
Shut Down
Setting 2
Time 2
Possible
LOBAT
Check
Off