SAM7SE256 Atmel Corporation, SAM7SE256 Datasheet - Page 30

no-image

SAM7SE256

Manufacturer Part Number
SAM7SE256
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7SE256

Flash (kbytes)
256 Kbytes
Pin Count
144
Max. Operating Frequency
48 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
88
Ext Interrupts
88
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
1
Twi (i2c)
1
Uart
3
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
External Bus Interface
1
Dram Memory
sdram
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
9.1
9.1.1
9.2
30
Reset Controller
Clock Generator
SAM7SE512/256/32
Brownout Detector and Power On Reset
The SAM7SE512/256/32 embeds one brownout detection circuit and a power-on reset cell. The
power-on reset is supplied with and monitors VDDCORE.
Both signals are provided to the Flash to prevent any code corruption during power-up or power-
down sequences or if brownouts occur on the VDDCORE power supply.
The power-on reset cell has a limited-accuracy threshold at around 1.5V. Its output remains low
during power-up until VDDCORE goes over this voltage level. This signal goes to the reset con-
troller and allows a full re-initialization of the device.
The brownout detector monitors the VDDCORE and VDDFLASH levels during operation by
comparing it to a fixed trigger level. It secures system operations in the most difficult environ-
ments and prevents code corruption in case of brownout on the VDDCORE or VDDFLASH.
When the brownout detector is enabled and VDDCORE decreases to a value below the trigger
level (Vbot18-, defined as Vbot18 - hyst/2), the brownout output is immediately activated.
When VDDCORE increases above the trigger level (Vbot18+, defined as Vbot18 + hyst/2), the
reset is released. The brownout detector only detects a drop if the voltage on VDDCORE stays
below the threshold voltage for longer than about 1µs.
The VDDCORE threshold voltage has a hysteresis of about 50 mV, to ensure spike free brown-
out detection. The typical value of the brownout detector threshold is 1.68V with an accuracy of
± 2% and is factory calibrated.
When the brownout detector is enabled and VDDFLASH decreases to a value below the trigger
level (Vbot33-, defined as Vbot33 - hyst/2), the brownout output is immediately activated.
When VDDFLASH increases above the trigger level (Vbot33+, defined as Vbot33 + hyst/2), the
reset is released. The brownout detector only detects a drop if the voltage on VDDCORE stays
below the threshold voltage for longer than about 1µs.
The VDDFLASH threshold voltage has a hysteresis of about 50 mV, to ensure spike free brown-
out detection. The typical value of the brownout detector threshold is 2.80V with an accuracy of
± 3.5% and is factory calibrated.
The brownout detector is low-power, as it consumes less than 20 µA static current. However, it
can be deactivated to save its static current. In this case, it consumes less than 1µA. The deac-
tivation is configured through the GPNVM bit 0 of the Flash.
The Clock Generator embeds one low-power RC Oscillator, one Main Oscillator and one PLL
with the following characteristics:
• Based on one power-on reset cell and a double brownout detector
• Status of the last reset, either Power-up Reset, Software Reset, User Reset, Watchdog
• Controls the internal resets and the NRST pin output
• Allows to shape a signal on the NRST line, guaranteeing that the length of the pulse meets
• RC Oscillator ranges between 22 KHz and 42 KHz
Reset, Brownout Reset
any requirement.
6222F–ATARM–14-Jan-11

Related parts for SAM7SE256