SAM7SE256 Atmel Corporation, SAM7SE256 Datasheet - Page 341

no-image

SAM7SE256

Manufacturer Part Number
SAM7SE256
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7SE256

Flash (kbytes)
256 Kbytes
Pin Count
144
Max. Operating Frequency
48 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
88
Ext Interrupts
88
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
1
Twi (i2c)
1
Uart
3
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
External Bus Interface
1
Dram Memory
sdram
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
31.7.5
Name:
Access:
• RDRF: Receive Data Register Full
0 = No data has been received since the last read of SPI_RDR
1 = Data has been received and the received data has been transferred from the serializer to SPI_RDR since the last read
of SPI_RDR.
• TDRE: Transmit Data Register Empty
0 = Data has been written to SPI_TDR and not yet transferred to the serializer.
1 = The last data written in the Transmit Data Register has been transferred to the serializer.
TDRE equals zero when the SPI is disabled or at reset. The SPI enable command sets this bit to one.
• MODF: Mode Fault Error
0 = No Mode Fault has been detected since the last read of SPI_SR.
1 = A Mode Fault occurred since the last read of the SPI_SR.
• OVRES: Overrun Error Status
0 = No overrun has been detected since the last read of SPI_SR.
1 = An overrun has occurred since the last read of SPI_SR.
An overrun occurs when SPI_RDR is loaded at least twice from the serializer since the last read of the SPI_RDR.
• ENDRX: End of RX buffer
0 = The Receive Counter Register has not reached 0 since the last write in SPI_RCR
1 = The Receive Counter Register has reached 0 since the last write in SPI_RCR
• ENDTX: End of TX buffer
0 = The Transmit Counter Register has not reached 0 since the last write in SPI_TCR
1 = The Transmit Counter Register has reached 0 since the last write in SPI_TCR
• RXBUFF: RX Buffer Full
0 = SPI_RCR
1 = Both SPI_RCR
6222F–ATARM–14-Jan-11
TXBUFE
31
23
15
7
SPI Status Register
(1)
or SPI_RNCR
RXBUFF
(1)
and SPI_RNCR
30
22
14
SPI_SR
Read-only
6
(1)
has a value other than 0.
ENDTX
29
21
13
(1)
5
have a value of 0.
ENDRX
28
20
12
4
OVRES
27
19
11
3
MODF
(1)
(1)
26
18
10
2
or SPI_RNCR
or SPI_TNCR
(1)
SAM7SE512/256/32
(1)
or SPI_RNCR
or SPI_TNCR
TXEMPTY
TDRE
(1)
(1)
25
17
9
1
.
.
(1)
(1)
.
.
SPIENS
NSSR
RDRF
24
16
8
0
341