SAM7SE256 Atmel Corporation, SAM7SE256 Datasheet - Page 575

no-image

SAM7SE256

Manufacturer Part Number
SAM7SE256
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7SE256

Flash (kbytes)
256 Kbytes
Pin Count
144
Max. Operating Frequency
48 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
88
Ext Interrupts
88
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
1
Twi (i2c)
1
Uart
3
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
External Bus Interface
1
Dram Memory
sdram
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
38.6.2
Name:
Access:
This register is used to get and set the device state as specified in Chapter 9 of the USB Serial Bus Specification, Rev.2.0.
• FADDEN: Function Address Enable
Read:
0 = Device is not in address state.
1 = Device is in address state.
Write:
0 = No effect, only a reset can bring back a device to the default state.
1 = Sets device in address state. This occurs after a successful Set Address request. Beforehand, the UDP_FADDR regis-
ter must have been initialized with Set Address parameters. Set Address must complete the Status Stage before setting
FADDEN. Refer to chapter 9 of the Universal Serial Bus Specification, Rev. 2.0 for more details.
• CONFG: Configured
Read:
0 = Device is not in configured state.
1 = Device is in configured state.
Write:
0 = Sets device in a non configured state
1 = Sets device in configured state.
The device is set in configured state when it is in address state and receives a successful Set Configuration request. Refer
to Chapter 9 of the Universal Serial Bus Specification, Rev. 2.0 for more details.
• ESR: Enable Send Resume
0 = Mandatory value prior to starting any Remote Wake Up procedure.
1 = Starts the Remote Wake Up procedure if this bit value was 0 and if RMWUPE is enabled.
6222F–ATARM–14-Jan-11
31
23
15
7
UDP Global State Register
30
22
14
UDP_GLB_STAT
6
Read-write
29
21
13
5
RMWUPE
28
20
12
4
RSMINPR
27
19
11
3
ESR
26
18
10
2
SAM7SE512/256/32
CONFG
25
17
9
1
FADDEN
24
16
8
0
575