SAM7SE256 Atmel Corporation, SAM7SE256 Datasheet - Page 652

no-image

SAM7SE256

Manufacturer Part Number
SAM7SE256
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7SE256

Flash (kbytes)
256 Kbytes
Pin Count
144
Max. Operating Frequency
48 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
88
Ext Interrupts
88
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
1
Twi (i2c)
1
Uart
3
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
External Bus Interface
1
Dram Memory
sdram
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
43.2
43.2.1
43.2.1.1
43.2.1.2
43.2.1.3
43.2.1.4
43.2.1.5
43.2.1.6
652
SAM7SE512/256/32 Errata - Rev. A Parts
SAM7SE512/256/32
Analog-to-Digital Converter (ADC)
ADC: DRDY Bit Cleared
ADC: DRDY not Cleared on Disable
ADC: DRDY Possibly Skipped due to CDR Read
ADC: Possible Skip on DRDY when Disabling a Channel
ADC: GOVRE Bit is Not Updated
ADC: GOVRE Bit is not Set when Reading CDR
Refer to
The DRDY Flag should be clear only after a read of ADC_LCDR (Last Converted Data Regis-
ter). A read of any ADC_CDRx register (Channel Data Register) automatically clears the DRDY
flag.
None
When reading LCDR at the same instant as an end of conversion, with DRDY already active,
DRDY is kept active regardless of the enable status of the current channel. This sets DRDY,
whereas new data is not stored.
None
Reading CDR for channel "y" at the same instant as an end of conversion on channel "x" with
EOC[x] already active, leads to skipping to set the DRDY flag if channel "x" is enabled.
Use of DRDY functionality with access to CDR registers should be avoided.
DRDY does not rise when disabling channel "y" at the same time as an end of "x" channel con-
version, although data is stored into CDRx and LCDR.
None.
Read of the Status Register at the same instant as an end of conversion leads to skipping the
update of the GOVRE (general overrun) flag. GOVRE is neither reset nor set.
For example, if reading the status while an end of conversion is occurring and:
None
When reading CDRy (Channel Data Register y) at the same instant as an end of conversion on
channel "x" with the following conditions:
1. GOVRE is active but DRDY is inactive, does not correspond to a new general overrun
2. GOVRE is inactive but DRDY is active, does correspond to a new general overrun con-
• EOC[x] already active,
Problem Fix/Workaround:
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
condition but the GOVRE flag is not reset.
dition but the GOVRE flag is not set.
Section 43.1 “Marking” on page
651.
6222F–ATARM–14-Jan-11

Related parts for SAM7SE256