Figure 9.29 shows the procedure for recovering from deep-power-down mode.
Note: Before transitioning to or recovering from deep-power-down mode it is necessary to halt
SDRAM access to the affected channels. Consequently, it is not possible to transition to or
recover from deep-power-down mode while programs or DMA operations that access
SDRAM are in progress. Pay attention to the following points when writing programs.
• Before transitioning to deep-power-down mode, halt any DMA channel transfers that
• Make sure that programs run while transitioning to deep-power-down mode, while in
access the SDRAM area of the affected channels.
deep-power-down mode, or while recovering from deep-power-down mode do not
access operands or fetch (or pre-fetch) instructions stored in the SDRAM area.
Figure 9.29 Procedure for Recovery from Deep-Power-Down Mode
Deep-power-down mode
End deep-power-down mode
(1) Confirm that all status bits in SDSTR have been cleared to 0
(2) Clear deep-power-down enable bit to 0 by means of program assigned to
Standby
Use a timer, etc., to wait for the same duration as the standby time specified
in the power-on sequence (determined by specifications of SDRAM used)
Initialization sequence
(1) Set initialization sequence start bit (DINIRQm) to 1 by means of program
(2) Wait for initialization sequence start bit (DINISTm) to be cleared to 0
Mode register setting
(1) Perform mode register setting
(2) Perform extended mode register setting
Start auto-refresh
Set DRFEN bit in SDRFCNT1 to 1
Access enabled status
(EXENB = 1)
other than to corresponding channel area
assigned to other than to corresponding channel area
Rev. 2.00 Sep. 07, 2007 Page 271 of 1312