20.3.19 IEBus Receive Interrupt Enable Register (IEIER)
IEIER enables/disables interrupts for sources such as IERSR receive busy, receive start, receive
normal completion, and receive error completion.
IEIER is initialized by a power-on reset or in deep standby.
Bit
7
6
5
4
Bit Name
RXBSYE
RXSE
RXFE
RXEDEE
Initial value:
Initial
Value
0
0
0
0
R/W:
Bit:
BYSE
R/W
R/W
R/W
R/W
R/W
R/W
RX
7
0
R/W
RX
SE
6
0
Description
Receive Busy Interrupt Enable
Enables/disables a receive busy interrupt (RXBSY)
0: Disables a receive busy (RXBSY) interrupt
1: Enables a receive busy (RXBSY) interrupt
Receive Start Interrupt Enable
Enables/disables a receive start (RXS) interrupt
0: Disables a receive start (RXS) interrupt
1: Enables a receive start (RXS) interrupt
Receive Normal Completion Enable
Enables/disables a receive normal completion (RXF)
interrupt
0: Disables a receive normal completion (RXF) interrupt
1: Enables a receive normal completion (RXF) interrupt
Broadcast Receive Error Interrupt Enable
Enables/disables a broadcast receive error (RXEDE)
interrupt
0: Disables a broadcast receive error (RXEDE) interrupt
1: Enables a broadcast receive error (RXEDE) interrupt
R/W
Section 20 IEBus
RX
FE
5
0
EDEE
R/W
RX
4
0
OVEE
R/W
RXE
3
0
RTMEE
Rev. 2.00 Sep. 07, 2007 Page 923 of 1312
R/W
RXE
TM
2
0
Controller (IEB) [R5S72612] [R5S72613]
DLEE
R/W
RXE
1
0
EPEE
R/W
RX
0
0
REJ09B0320-0200